Procedures to replace the brush/leveling stone of the T2 pad washing unit (Continued)
Step No.
Remove the hexagon socket head cap screws (3 pcs) and remove the leveling stone
10
together with the holder.
・The size for the hexagon socket head cap screws is M5 for the DFG8540/DFP8140, and
・Do not adjust the 3 set screws next to the hexagon socket head cap screws. The 3 set
Remove the leveling stone after loosening the set screws (3 pcs) at the lateral side of the
11
holder.
・The size for the set screws is M5 for the DFG8540/DFP8140, and M4 for the
#tnl2019-0008e-rev1
# 4 / 5
M4 for the DFG8560/DFP8160.
screws are for adjusting the level of the leveling stone.
Set screw
Hexagon socket head cap
screw
DFG8560/DFP8160.
Procedure
Holder
Leveling stone
Leveling stone
Set screw
Holder
Set screw