ARO PM20 Series Руководство по эксплуатации - Страница 9

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Водяной насос ARO PM20 Series. ARO PM20 Series 13 страниц.

ARO PM20 Series Руководство по эксплуатации
Product discharged from exhaust outlet.
Check for diaphragm rupture.
y
Check tightness of (14) diaphragm screw.
y
Air bubbles in product discharge.
Check connections of suction plumbing.
y
Check "O" rings between intake manifold and inlet side
y
fluid caps.
Check tightness of (14) diaphragm screw.
y
Motor blows air or stalls.
Check (176) check valve for damage or wear.
y
Check for restrictions in valve / exhaust.
y
(Dimensions shown are for reference only, they are displayed in inches and millimeters (mm)).
21-5/8" (548.2 mm)
16-3/16" (411.1 mm)
3"(76.2mm)
Dotted lines show optional
67263 mu er assembly.
Dotted lines show optional
67213 mu er kit.
PM20X-X-X-BXX (en)

TROUBLESHOOTING

DIMENSIONAL DATA

2-1/2" Sanitary Flange
2-1/2" Sanitary Flange
12" (304.8 mm)
3/4 - 14 NPTF
26-9/32"
(667.4 mm)
9-1/16"
Exhaust Port
1-1/2 - 11-1/2 NPTF
(230.2 mm)
10-1/16"
2-1/2" Sanitary Flange
(255.6 mm)
Low output volume, erratic flow, or no flow.
Check air supply.
y
Check for plugged outlet hose.
y
Check for kinked (restrictive) outlet material hose.
y
Check for kinked (restrictive) or collapsed inlet material
y
hose.
Check for pump cavitation -- suction pipe should be sized
y
at least as large as the inlet thread diameter of the pump
for proper flow if high viscosity fluids are being pumped.
Suction hose must be a non-collapsing type, capable of
pulling a high vacuum.
Check all joints on the inlet manifolds and suction con-
y
nections. These must be air tight.
Inspect the pump for solid objects logged in the dia-
y
phragmchamber or the seat area.
19-11/32" (491.3 mm)
OUTLET
Air Inlet
INLET
9/16" Slot (14.3 mm)
10-1/16"
(255.6 mm)
Figure 4
24-3/4"
(628.7 mm)
13-9/16"
(344.5 mm)
2-1/2"
(63.5 mm)
Page 9 of 12