TherMiser TME operation

2. Advanced settings

2.1 ENTERING INTO ADVANCED SETTINGS MENU*
Press
so that the screen is off.
Then press and hold
+
together. The unit enters
the menu at Status 1: "SEN" and in Function 00 (flashing).
MENU NO.
ICON
1
SEN
2
OSV
3
DIF
4
SFH
5
SVL
6
ADJ
7
FRE
8
PON
9
FAC
2.2 LOCK SCREEN/MENU
To prevent tampering and adjustment of the TherMiser unit, unit, press
seconds
appears. To unlock, press
*
These are advanced settings and should be adjusted with caution.
To adjust the settings press
FUNCTION
Controls sensor inputs
Upper limit of external/ThermaSkirt sensing temp,
Differential hysteresis between off and on again
of external temp.
Room temperature upper limit
Room temperature lower limit
Calibrates tem of unit to the room, compensating
for external factors.
Frost protection
Power on memory
Factory reset
for 5
for 5 seconds
flashes then disappears.
Visit
www.discreteheat.com/thermiser
To move through menu Items 1-7 press the
or
See the menu below
OPTIONS
00: Built-in temp sensor only
01: External temp sensor only
02: Built in temp and External Skirting Temp Sensor
Note: If no external sensor fitted,"ERR" message
displays, unit will not function
5~99°C
1~9°C
5~99°C
5~99°C
-5~+5°
00: Frost protection OFF
01: Frost protection ON. 5°C
00: Auto memory, no power
01: NO power = no memory
Adjust using
then press
factory settings
2.3 LOCK SCREEN/MENU
Manual Override
. Press
or
and
if heat required. Automatically resets to program mode at next time interval.
for more information
FACTORY SETTING
00
42°C
2°C
35°C
5°C
0°C
00
00
until"00"
to restore
00
to override current target temp.
button.
appears