26 BIT WIEGAND SPECIFICATIONS:
The following WIEGAND output is sent each time the # (enter)
key is pressed.
P S S S S S S S S N N N N N N N N N N N N N P
BIT
1 2
BIT
1 is an even parity for the following 12 bits.
The sum of bits 1-13 is even.
BITS
2-9 are the programmable SITE CODE. While
pressing * during the first 3 seconds on power up
it is possible to program the site code. Any number
from 000 to 255 is possible.
BITS
10-25 this is the number entered prior to pressing
# (enter). Leading 0's are added as required.
Bit 10 is most significant.
BIT
26 Odd parity over previous 12 bits. The sum of bits
14-26 is odd.
EXAMPLE: A card code of 123 entered:
1 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 0 1 1 1
(site code 004)
The data is sent at 2 msec per bit with a pulse duration
of 70 μsec
A buzzer beeps with each key press.
Note: Camden Piezo Proximity readers plus Keypad are
programmed with default Site Code "000". The maximum
Site Code is 255.
Example to set site code to 100. Disconnect the power
supply for a minimum of 10 seconds. Connect the power
supply, and the unit will start beeping. During the first 5
seconds perform the following:
Enter *
The keypad enters programming mode,
the red LED flashes.
Enter 100 #
The site code of 100 is assigned.
Push Buttons
Keypads
5502 Timberlea Blvd.,
Mississauga, ON Canada
L4W 2T7
9 10
25 26
Strikes
Magnetic Locks
www.camdencontrols.com
Toll Free: 1.877.226.3369
Model CV-634PR Piezo Proximity Reader Manual
1. Blue Wire - PRESSING any key on the keypad will generate
a 30 second 0.25 amp intermittent duty grounding output.
2. Orange Wire - When the Hold Line, Orange wire, is pulled
"low", any codes entered on the keypad are stored in the
buffer. When the Hold Line is released to logic "high" – the
buffered code data is sent.
2. Grey Wire - When the photodiode senses ambient light
the Grey wire is pulled "LOW"
An error code is generated by any of the following:
a) Pressing the # key with no preceding digits;
b) Pressing any number of only zero's prior to
pressing the # key, or;
c) Pressing 65,535 or any number above 65,535.
An Error Code will send all binary 1's to your panel.
DO NOT Program your panel to accept code number 65,535.
Key Switches
File: CV-634PR Instructions..indd- Rev1
Revised: July 4th, 2014
Part No: 40-82B042
Relays & Timers
Access Control