CAMDEN CX-WC17VR-PS Series Руководство по установке - Страница 4

Просмотреть онлайн или скачать pdf Руководство по установке для По замкам CAMDEN CX-WC17VR-PS Series. CAMDEN CX-WC17VR-PS Series 6 страниц. Restroom kit

120 VAC
Transformer
CX-TRX-5024
24 VAC, 50 VA
PUSH
PUSH
TO OPEN
TO OPEN
A
B
CM-7536VR/4
CM-7536VR/4
Outside
Inside
Push to Open
Push to Open
CX-WC17VR-PS Wiring Diagram
PUSH
TO
LOCK
C
1. CX-33 can be set to Mode 7 (Normally Unlocked)
or Mode 8 (Normally Locked).
Notes
CM-7536VR/8B
2. Mode 7 = Set Strike to Fail Safe.
Push to Lock
3. Mode 8 = Set Strike to Fail Secure.
AC
+ Lock
AC
+ Strike
Outside
- Strike
Push To Open
*
Inside
Door
Push To Open
Operator
Push To
*
Lock
Green LED
Red LED
DPS NC
DPS COMM
*
+
WET
+ VDC
- INPUT
- VDC
Model: 60-40E033
Door Position Switch
N.C.
CX-WC17VR-PS SERIES RESTROOM KIT
Electric Strike
CX-ED2079
MOV
Wire MOV
directly to
strike or
magnet
Door Operator
CM221
Mode Pins:
OPEN (Default position) = Internal mode;
LED colors will be controlled by the IR Sensor
SHORTED = Extermal mode; LED colors will be
controlled by Yellow and White wires.
Distance Adjustment
(2" to 8", 5 to 20 cm)
Turn clockwise
to increase range
12 to 24 V DC (+)
0 V DC (Ground) (-)
Green LED
Red LED
Relay - Normally Open
Relay - Common
Relay - Normally Closed
CAMDEN DOOR CONTROLS
JML
Aug 24, 2022
SCALE: NONE
DRAWN BY:
DATE:
CX-WC17VR-PS Wiring Diagram
DRAWING No:
FILENAME:
INSTALLATION INSTRUCTIONS
Time Adjustment
(0.5 to 20 seconds)
For ToggleTurn
clockwise to increase
time delay
5502 Timberlea Blvd
Mississauga, Ontario
L4W 2T7
1
REV: