Abbyy USA W80F600UTBAA Сервисный бюллетень - Страница 2

Просмотреть онлайн или скачать pdf Сервисный бюллетень для Посудомоечная машина Abbyy USA W80F600UTBAA. Abbyy USA W80F600UTBAA 4 страницы. Top control dishwasher with stainless steel tub

Solutions:
1. Water Leak from Door Corners:
Level the dishwasher.
Change the main PCB (refer to the chart below).
2. oE Error Code:
Check the tub and make sure there is no water left after a drain cycle.
• If water is left in the tub, check the operation of the drain pump and inspect
the condition of the drain hose.
• Check the sensor hose from the sump to the case brake for obstructions.
Open the door after filling the tub with water and make sure the water level is correct.
Check the water level in the overflow chamber on the case brake.
If all of the above is normal. Replace the main PCB and the case brake assy (refer to
the chart below).
Sensor Hose
3. 5E Drain Error Code:
Check for obstructions in the drain hose.
Check the wiring connection on the drain pump.
Check the resistance of the drain pump. The drain pump should measure 25Ω.
Even if the drain pump and drain hose check good, replace the main PCB. The main
PCB software has been updated. It will no longer detect the water level by the ECS.
4. Dishwasher does not complete the cycle:
Check the heater resistance for 13.5Ω.
If the heater resistance does not measure 13.5Ω, replace the heater and the main PCB
together.
How to Check the Software Version:
The new software version is number 5840. To check the software version, enter the service test
mode by pressing the Power, Delicate, and Heavy keys at the same time. The software version will be
displayed as soon as the service test mode is entered.
DW80F800 will show a "40" in the delay start display
DW80F600 will turn on numerous LED's. Verify that the Smart Auto, Heavy, and 6 hr. LED's are
illuminated. This indicates software version 5840. Other LED's will illuminate, however, these LED's
indicate software versions for the sub PCB and key panel.
Parts Replacement Chart:
This information is published for informational purposes only and intended for use only by personnel qualified for the specific tasks
depicted. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding
potential hazards when handling or servicing a product. Only qualified personnel should repair products powered by electricity. Any
attempt to handle, service or repair the product or products by anyone other than qualified personnel could result in serious injury or
death. You agree that your use of and reliance on this information is at your sole risk. This information is subject to change or update
without notice. There are no warranties, either expressed or implied, regarding the accuracy or completeness of this information.
Water level in the
tub
Water level in the