CAME A 5024 N Руководство по установке - Страница 8
Просмотреть онлайн или скачать pdf Руководство по установке для Открыватель двери гаража CAME A 5024 N. CAME A 5024 N 13 страниц. Ati series
Также для CAME A 5024 N: Руководство по установке (13 страниц)

Securing and adjusting the endstop
Stop brake microswitch
OPENING PHASE: (stop)
Release the gearmotor and swing the gate-leaf to the fully open
position you desire, then, unscrew the securing screws on the opening
stop micro-switches assembly.
Slide the micro-switch assembly along the micro-switch bar until it is
inserted by contact on the micro-switch activating sled
Secure the micro-switch assembly using the respective screws.
Part. A.
Release the gearmotor and swing the gate-leaf to the fully open position you desire, then, unscrew the securing screws on the opening stop
micro-switches assembly.
Slide the micro-switch assembly along the micro-switch bar until it is completely passing the contact point on the micro-switch activating sled (as
shown in part B.).
Secure the micro-switch assembly using the respective screws.
Part. B.
Microswitch bar
Cable support
Micro-switch
insertion area
OPENING PHASE (deceleration if set up on the control panel):
Closing-speed brake microswitch
Spindle
Spindle
CLOSING PHASE (deceleration)
Swing the gate until fully closed.
Unscrew the securing screws on the closing decelaration micro-switch
assembly.
Slide the micro-switch assembly along the micro-switch bar until it is
completely passing the contact point on the micro-switch activating sled
(as shown in part A.)
Secure the micro-switch assembly using the respective screws.
Excluding the micro-switch contact (fully
open gate-leaf)
Endless screw
Microswitch actuating sled
Excluding the micro-
switch contact (fully
closed gate-leaf)
Deceleration micro-switch
insertion area