CAME BX241 Руководство по установке - Страница 9

Просмотреть онлайн или скачать pdf Руководство по установке для Открыватель двери гаража CAME BX241. CAME BX241 17 страниц. Automation systems for sliding gates
Также для CAME BX241: Руководство (20 страниц), Руководство (20 страниц)

CAME BX241 Руководство по установке
6.3 Description board BN1
The BN1 board allows the automation to be battery operated in case of a power outage. When power is restored, the card also
recharges the batteries.
1
1 - ZBX241 board connecting terminal board
2 - The green LED indicator light signals mains power supply on
3 - The red LED indicator light signals emergency battery power supply on
6.4 Emergency battery connection
Insert batteries in the appropriate bracket (Fig.1) and connect them (using the cables provided) to the ZBX241 board (Fig.2)
terminal (+,-).
Battery bracket
6.5 Gearmotor end-stop connection
The motor and limit switch unit are wired at the factory for mounting on the left-hand side of the gate (as seen from the inside).
If right-hand installation is desired:
- invert limit switch connections FA-FC on the terminal block;
- invert motor phase connections M-N on the terminal block.
FA
FC
F
NC
NC
Limit switch unit
FIG.1
Bridge connection
lead
M
N
M
24V (d.c.) single-phase motor
2
3
12V - 1.2 Ah emergency batteries
NOT INCLUDED
ZBX241 board
+ SENS. -
FA
FC
NC
NC
Limit switch unit
10 11 E1 1
2
3
3P C1 C3 7
PROGRAM.
CH1
+ T.A.C. -
+ T.P.A. -
F
M
N
M
24V (d.c.) single-phase motor
FIG.2
9