CAME ZL19N Руководство по установке - Страница 8

Просмотреть онлайн или скачать pdf Руководство по установке для Открыватель двери гаража CAME ZL19N. CAME ZL19N 17 страниц. Control panel for 24v gearmotors

CAME ZL19N Руководство по установке

Safety devices

(N.C.) "partial stop" contact
Input for safety devices like photocells, sensitive edges and other
devices that comply with EN 12978 regulations. Stops gate leaves
if they are moving and then automatically closes them.
If unused set DIP switch n.8 to ON.
C1=Reopening when closing (N.C.) Contact»
Input for safety devices like photocells, sensitive edges and other
devices that comply with EN 12978 regulations. While the gate is
closing, opening the contact will invert movement until it is fully
openend.
If unused set DIP switch n.10 to ON.
(N.C.) "partial stop" contact
C1=Reopening when closing (N.C.) Contact»
DIR
RX
RX
Delta
Delta-S
TX
TX