An identification tag is permanently mounted
1.
on the cabinet.
D
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
Plug the unit into a properly grounded
receptacle ONLY. Arcing will occur when
2.
connecting or disconnecting the unit unless
all controls are in the "OFF" position.
Position the unit so the cord is easily accessible
3.
in case of any emergencies. If necessary, a
proper receptacle or outlet configuration, as
required for the unit, must be installed by a
licensed electrician in accordance with
applicable, local electrical codes.
D
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
N G E R
N G E R
125
1
50/60
/
VOLTAGE PHASE CYCLE
HZ
AMPS
230
1
50/60
# 8 2 0 O p e r a t i o n a n d C a r e M a n u a l • 5.
E L E C T R I C A L I N S T A L L A T I O N
230V:
To prevent an electrical shock hazard between the
appliance and other appliances or metal parts in
close vicinity, an equalization-bonding stud is
provided. An equalization bonding lead must be
connected to this stud and the other appliances /
metal parts to provide sufficient protection
against potential difference. The terminal is
marked with the following symbol.
NOTE: The appliance must be connected to an
electrical circuit that is protected by an
external GFCI outlet.
D
D
ELECTRICAL
8.0 1.00
kW
5-15
NEMA
4.1
.95
6-15
NEMA
(
)
USA ONLY
7/7, 220-230
CEE
I N S T A L L A T I O N
N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
N G E R
IMPROPER INSTALLATION,
ALTERATION, ADJUSTMENT,
SERVICE, OR MAINTENANCE COULD
RESULT IN SEVERE INJURY, DEATH
OR CAUSE PROPERTY DAMAGE.
READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.
, 15A-125
P
V PLUG
, 15A-250
P
V PLUG
V PLUG