TB0224.fm — R2200 Has Delayed Start-Up when CMOS Battery is Replaced
OVERVIEW / ENVIRONMENT
When the CMOS backup battery is replaced on an R2200 blade, the first start-up takes much longer than
normal. This occurs only on the first start-up after changing the battery. After this start-up, behavior is normal.

DETAILED DESCRIPTION

When the CMOS backup battery is removed and replaced on an R2200 blade, the first start-up after the
replacement takes much longer than normal. In addition, when the blade is reinserted into a powered-up
chassis, it does not automatically power on. Instead, the system administrator must physically press the
power button to turn the R2200 on. At that time, the R2200 uses the previously programmed power-on
state to define its start-up sequence. If this state was set to Last Saved State or Power Off, the adminis-
trator needs to either press the power button to force the blade to turn on, or turn on the blade remotely
using Sentral or Switch Manager, or by sending a Wake on LAN packet.
When the blade starts up, it enters Power-On Self-Test (POST) and hangs at POST code 60 (a memory
initialization state) for slightly less than five minutes. This is a one-time event and is self-clearing. This
issue occurs only on the first start-up after changing the battery. After this start-up, behavior is normal.
This issue applies only to R2200s with BIOS version 2.00 or earlier.
RESOLUTION
No workaround is available at this time. A correction in a future BIOS version is anticipated.
For more information, please contact ClearCube technical support.
support.clearcube.com
(866) 652-3400
+1 (512) 652-3400
ClearCube Technology
8834 Capital of Texas Hwy N
R2200 Has Delayed Start-Up when CMOS Battery is Replaced
R2200 Blade
October 24, 2006
Email address for ClearCube Technical Support
ClearCube Support Website
Direct line in the US
Direct line from outside the US
Austin, Texas 78759
ClearCube Public Technical Document
Document Code: TB0224JS
TB0224 rev 10/24/2006
voice 512 652 3500 www.clearcube.com