COLLABORATE® Versa™ Room CT 160
Above the Ceiling Mount
Select hardware based on your specific installation needs.
Note: It is the installer's responsibility to ensure that the installation and cable routing complies with local safety
codes.
1. Determine location for the mount, and where to route cables.
Mark location where you want to route cables through with a pencil (on finished side of ceiling tile) if you need to
cut a hole.
2. Remove affected ceiling tile and adjacent tiles required for access.
3. Install fasteners/anchors.
4. Install the Versa USB at determined location.
5. Use a drywall saw to cut a hole into finished side of ceiling tile at marked location.
6. Route the cables through the hole.
Note the following:
Carefully run connected cables so they do not block the cooling vents or put strain on the connectors.
•
Anchors and screws used to mount the Versa USB are not provided and must be selected by installer for the
•
type of ceiling material supporting the unit. Take care while drilling and installing anchors so ceiling material
does not tear out and weaken attachment.
Mount the Versa Hub, UNITE 160 4K Camera, and Ceiling Loudspeakers
Follow the instructions in the respective Quick-Start or Installation Guide (included).
Connect the Components
Warning:
Power over Ethernet (PoE) equipment used with Xceed BMA Room must meet the IEEE 802.3af or 802.3at
standards.
You should use the PoE Power Injector provided with Xceed BMA Room. Other power source equipment may
immediately apply power and could damage the Xceed BMA Room components.
Complete step 1 NOW if you did not when you installed the BMA CTH with the surface mount kit.
1. On the BMA CTH back panel, do the following:
•
With speaker wire (not included), connect the two loudspeakers to the Phoenix Euroblock connectors (a)
•
Move the Power Select sliding switch (b) to the right, towards the P-Link In connector (c)
a
2. On the Versa USB, set the Power select switch (h) towards PoE In.
e
6
c
b
f
h
g
d
i
Quick-Start Guide
QSG-0169-001v1.0 May 2023