5.3. INSTALLATION
Fireplace for central heating may be connected to open system (Fig. 5) and closed
system (Fig. 6) of central heating installation, since this has built-in thermal
protection – heat exchanger. Thermal valve is not in the basic equipment of the
fireplace.It is advisable to install fireplace onto central heating open system, and in
any case, it is compulsory to install thermal valve with the probe onto the fireplace
and connection of the heat exchanger to the water system. Without installation of
thermal valve, guarantee is null.All connections on fireplace must be well sealed,
which should be visually checked prior to commissioning. Mounting procedure is
finished with water filling of entire fireplace and entire installation up to the
necessary pressure.
FIREPLACE MAY NOT BE USED WITHOUT WATER.
Fig. 5 Diagram of the connection of fireplace to central heating open system
5
2
13
12'
1
1. Fireplace Vulkan (back)
2. Smoke pipe
3. Open expansion vessel
4. Conductive pipe
5. Manometer
6. Radiator valve
7. Radiator
8. Exhaust valve
9. Circular pump
9
11
12
10
15
14
3
4
6
7
10. Check valve
11. Pressure duct
12. Connecting duct for water system
12'. Hot water exhaust
13. Thermal valve probe
14. Connection for filling and discharging 1/2"
15. Return duct
5
8