Preparing the
ceiling hole
Preparing the ceiling hole
1
Prepare a ceiling hole in the bath room
measuring 450x350mm. Caution:
1.
Provide at least 20cm of spacing between the wall
and the air intake for removing and installing the
filter.
2.
When installing near any doors, make sure there is
enough clearance provided so that the door does
not hit the unit.
350mm
Ceiling must be capable of handling the weight of the
unit (7.2kg) and compensated where necessary.
Make sure the thickness of the ceiling is no more than
40mm, as the unit cannot be fitted if the ceiling is over
this thickness.
Installing the unit
2
・ Connect one end of the RJ45 cable into the RJ45 jack
of the unit (The other end will connect with the Wall
Panel or the Infrared Receiver).

Installation Steps

Installing
Electrical
the unit
Work
450mm
Ceiling
strength
Compensation
Wall Panel
Infrared Receiver
Installation
Installation
・ Install a 4-inch (10cm) duct to the unit' s exhaust
duct connector.
Secure the duct with duct tape or clamps.
Adjust the exhaust duct accordingly and make
sure the duct is not pinched, as this will constrict
air flow.
It is recommended that a bird guard be used
with your exterior exhaust vent to prevent birds
and rain from entering.
Tilt the unit into the ceiling opening.
・ Use the supplied M4.0 x 31.75mm self-tapping
screws to secure the unit onto the ceiling.
M4.0 x 31.75mm
・ Use the supplied M4.0 x 12mm self-tapping
screws to attach the Bottom Cover to the unit.
M4.0 x 12mm
Operational
Testing
(Continued on next page)