E.) Installing the Signal Cable
IT IS IMPERATIVE TO WRAP THE COIL THE CORRECT NUMBER OF TIMES.
PLEASE SEE CHART BELOW FOR CORRECT NUMBER OF WRAPS.
UNIT TYPE
Pipe Type
AG-100
Copper Pipe
AG-100
Copper Pipe
AG-100
Copper Pipe
AG-100
Copper Pipe
AG-100
PVC/CPVC/PEX
AG-100
PVC/CPVC/PEX
AG-100
PVC/CPVC/PEX
AG-100
PVC/CPVC/PEX
AG-200
Copper Pipe
AG-200
PVC/CPVC/PEX
AG-200
Ferrous Pipe
AG-300
Copper Pipe
AG-300
Copper Pipe
AG-300
PVC/CPVC/PEX
AG-300
PVC/CPVC/PEX
AG-300
Ferrous Pipe
AG-400
Copper Pipe
AG-400
Copper Pipe
AG-400
PVC/CPVC/PEX
AG-400
PVC/CPVC/PEX
AG-400
Ferrous Pipe
JUST BECAUSE YOU HAVE EXTRA WIRE DOES NOT MEAN YOU HAVE TO USE IT! DO NOT OVER WRAP THE COILS MORE
THAN THE RECOMMENDED NUMBER. DO NOT UNDER WRAP THE AMOUNT OF COILS SUGGESTED. Over wrapping can
significantly decrease the power of the signal. If you are unable to obtain correct number of wraps due to straight pipe issues of not giving
you enough space, the minimum number of wraps the unit requires is at least 30 wraps.
MAKE SURE THE WRAPS ARE FLUSH AGAINST ONE ANOTHER – NEVER OVERLAPPING. THIS IS EXTREMELY IMPORTANT.
AS PREVIOUSLY NOTED, MAKE SURE THE CONTROL BOX IS MOUNTED AS CLOSE AS POSSIBLE TO WHERE THE SIGNAL CAB E
IS WRAPPED ON THE PIPE. THE MAXIMUM DISTANCE SHOULD NOT BE MORE THAN 10 FEET.
1.
Single Wrap
to power
box terminal
Double Wrap
Triple Wrap
5.
Pipe Size
.75"
1"
1.25"
1.5"
.75"
1"
1.25"
1.5"
2"
2"
Call
2.5"
3"
2.5"
3"
Call
3.5"
4"
3.5"
4"
Call
Straight section of pipe away
from angles, tees, valves and couplings
Balance of ScaleBlaster
signal cable
Cable Tie
YOU MUST KEEP THE SECOND and/or THIRD WRAPPING IN THE SAME DIRECTION AS THE
FIRST! Wrap right over the top of the first layer continuing in the same wrapping direction as the first layer
– clockwise or counterclockwise. This second and/or third layer must also be tight and touching the prior
wrap.
3.
See wrap
maximum
chart
Type of Coil
Wire Gauge
Triple**
18
Triple**
18
Triple**
18
Triple**
18
Double*
18
Double*
18
Double*
18
Double*
18
Double*
12
Single
12
Call
12
Double*
12
Double*
12
Single
12
Single
12
Call
12
Double*
12
Double*
12
Single
12
Single
12
Call
12
2.
to power
box terminal
4.
6.
Page 7
(continued)
Wraps
*Example - Double
70
80 wraps is a total
68
of 160 wraps. 80
62
wraps on first layer
54
and 80 on second
80
layer
55
40
34
68
82
Call
64
**Example - Triple
60
70 wraps is a total
71
of 210 wraps. 70
61
wraps on first layer,
Call
70 on second layer
58
and 70 wraps on
56
third layer
52
40
Call
See wrap
maximum
chart
Cable Tie
Cable Tie
L