TROUBLESHOOTING TIPS

Fault / Display
No output voltage, buzzer sounds
continuously
No output voltage
Incorrect output voltage
Cannot power the load
Cause
Low input DC voltage
High input DC voltage
Overload
Over temperature
The switch is off
Poor cable connection
RMS Multimeter measurement error
The
battery
power
of
Multimeter is low.
Load is too
large,
or the actual
power of the appliance
exceeds nominal
power.
The starting power is larger than
rated power (such as motor).
Solutions
Recharge or replace the battery
Do not use it when the battery is charging.
Check the rated voltage of the battery and
make sure it is in within the range of the input
voltage.
Reduce the load.
Cut off the load and let cool for 10 to 30
minutes. Restart it after it returns to normal
temperature.
The load is too large, reduce
the total load to the range of rated power.
Avoid blocking the vent and improve the
ventilation
condition.
Reduce the ambient
temperature.
Turn on the power switch.
Check the cables and make sure they are tightly
connected and in good
Use a true RMS multimeter to
as
model FLUKE 177/179.
Try to maintain the input voltage in the range
RMS
of rated power. The input voltage may be too
high or too low.
Change the battery of the multimeter then test
again.
Reduce the
load,
then turn on the
appliance
first,
then turn on the inverter.
The internal inverter soft-start circuit will buffer
starting the appliance.
condition.
measure,
such