AIMS Power PWRIG150024120S Руководство по эксплуатации - Страница 6

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Инвертор AIMS Power PWRIG150024120S. AIMS Power PWRIG150024120S 16 страниц.

AIMS Power PWRIG150024120S Руководство по эксплуатации
 Prior to using this product please read this operation manual thoroughly. Inappropriate use may cause damage to the product!
Please check through this manual on your new inverter before operating.
I. Use of battery (DC power)
12V Battery: When using 500 watts of output (120V AC) with a 100A battery, you can use this product for 2 hours (4.2A used under 100W) in
optimal conditions.
24V Battery: When using 500 watts of output (120V AC) with a 100A battery, you can use this product for 4 hours (4.2A) used under 100W) in
optimal conditions.
48V Battery: When using 500 watts of output (120V AC) with a 100A battery, you can use this product for 8 hours (4.2A) used under 100W) in
optimal conditions.
II. Use of AC power outlet (120V AC)
The product has an output function of 120V AC.
Although the output AC cord is different based on thickness, 150 Ft. length can be used in general conditions.
III. Alarm display function (red LED)
 Output short circuit
 Output overload
 Over temperate protection
 Battery low voltage (alarm/LED)
 Battery high voltage (alarm/LED)
IV. Fan operation
Based on the 120V AC load of this product the fan automatically operates when the temperature increases.
Thermal fan engages at 113*F ±3*
6