AIMS Power PWRINV500012W Руководство по эксплуатации - Страница 6

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Инвертор AIMS Power PWRINV500012W. AIMS Power PWRINV500012W 13 страниц. Dc to ac power inverter

AIMS Power PWRINV500012W Руководство по эксплуатации
V 2.0
The other indicators should be off.
4. Set power inverter switch to the OFF position, the indicator lights may blink and the
internal alarm may sound momentarily. This is normal. Plug the test load into the AC
receptacle on the front panel of the inverter. Leave the test load switch off.
5. Set power inverter switch to the ON position and turn the test load on, the inverter should
supply power to the load. If you plan to measure the true output R.M.S. voltage of inverter, a
meter such as FLUKE 87A, BACKMAN 4410 or TRIPLETT 4200 must be used.

INSTALLATION

1. Where to install
The power inverter should be installed in a location that meets the following requirements:
a.
Dry - Do not allow water to drip or splash onto the inverter.
b.
Cool - Ambient air temperature should be between 0°C and 40°C, the cooler the better when
operating in this range
c.
Ventilation - Allow at least 12 inches of clearance around the inverter for air flow. Ensure the
ventilation openings on the rear and bottom of the unit are not obstructed.
d.
Safety - Do not install the inverter in the same compartment as batteries or in any compartment
capable of storing flammable liquids such as gasoline.
2. Cables
DC to AC inverters require high amperage/low voltage DC power to low amperage/high voltage AC
power. To operate properly, connect inverter DC input terminals direct to battery with heaviest wire
available see chart below:
12 Volt Model: 1 x set of 4/0 AWG (1 red + 1black) Recommended: 1ANL500KIT-500Amp fuse kit
24 Volt Model: 1 x set of 1/0 AWG (1 red + 1black) Recommended: 1ANL300KIT-300Amp fuse kit
36 Volt Model: 1 x set of 4 AWG (1 red + 1black) Recommended: 1ANL150KIT-150Amp fuse kit
48 Volt Model: 1 x set of 6 AWG (1 red + 1black) Recommended: 1ANL150KIT-150Amp fuse kit
Battery Cables Installation
When connecting the AC inverter to the battery terminals, it is important to connect the "+" wire to the
"+" terminal and the "-" wire to the "-" terminal. Do NOT reverse the polarity. It will void the warranty.
Make sure you connect negative to negative and positive to positive.