ADVANCED SETTINGS
Turn off the appliance. Then press and hold the
lower button for 4 seconds to enter temperature
regulation setting (see previous section). Then
once again press and hold the lower button for 4
seconds to enter the advanced settings.
Meaning of lit LEDs:
Blue and green → current function is disabled
Two red → current function is enabled
Advanced setting 1 – CONSTANT HEATING
Use [+] button to enable the function (default
setting).
Use [−] button to disable the function. It will be not
possible to activate the constant heating. Heating
time will be limited to maximum 180 minutes.
Accept and go to next advanced setting by
pressing the lower button (confirmed by "beep"
sound).
Advanced setting 2 – INSTANT HEATING
Use [+] button to enable the function. The
appliance will start heating for 60 minutes every
time the power supply is on.
Use [−] button to disable the function (default
setting).
Accept and go back to stand-by mode by pressing
the lower button (confirmed by "beep" sound).
4)
MAINTENANCE
EN | 14
Before carrying out any maintenance operation on your appliance,
ensure that it is switched off and cooled down.
Never use abrasive or corrosive products on the outer surfaces of
the appliance. Use warm, soapy water (except the electrical parts).
To clean the control box, use a soft, dry cloth without any solvents.
IMPORTANT: This appliance is filled with a precise quantity of
propylene glycol solution. Any repair requiring the fluid tank to be
opened should only be carried out by the manufacturer or their after
sales service department, which should also be contacted in the
event of an fluid leak. Minimum storage temperature of this
appliance is -10°C. After 5 years from production date anti-freeze
properties could decrease.
5)
GUARANTEE AND ADDITIONAL INFORMATION
Dated proof of purchase must be presented to activate the
guarantee. The guarantee does not cover radiator transport,
removal and installation costs.
The guarantee shall not apply if the appliance is installed, used or
maintained in a way that does not comply with standards in force in
the relevant country, good professional practice, or the
manufacturer's instructions.