The occupancy sensor offers 8 connection terminals:
Power supply:
L
230 VAC
N
Neutral
PE
Protective earth
R
Connection for slave
S
Switch for semi-automatic mode
9.
Operating instructions
All setting can be done by use of the infrared remote control. The settings are explained in the OEM manual that is
supplied with the product.
Mechanical alignment: The detection area is oval shaped. Install the unit in such a manner that the markings on the
housing are positioned in the longitudinal direction of the area to be monitored. Do not install sensors near heat
sources like air-conditioning units, lights or radiators.
10.
Troubleshooting
The functional indicators in the case of the ARTIDOR AR-024 (red and green LED's) have several functions.
Red and green LED indicating self-checking mode (over a period of 60 seconds following mains'-supply lock-on)
Flashing at intervals of 1 second
EEPROM / memory empty
Flashing rapidly
EEPROM / memory contains information
User manual explosion-safe AR-024 occupancy sensor
Issue April 2020
Potential free contact:
NO connection 1