djpower TOPCAT CAT-2 Руководство пользователя - Страница 9
Просмотреть онлайн или скачать pdf Руководство пользователя для Портативный генератор djpower TOPCAT CAT-2. djpower TOPCAT CAT-2 13 страниц.
5.3
DMX Mode & Operation
Machine CAT-2 works with a DMX controller.
• Connect the product to a suitable power outlet.
• Turn the product on.
• Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket on the product.
When connected with DMX controller and receiving DMX signal, the LCD display will always show current DMX starting address which can
be reset by pressing "▲"or "▼".
5.3.1
DMX Channel Assignments and Values
Channe
Function
l
1
Fan Speed
2
Fog Output
3
Work Mode
4
Forced pumping mode
5.4
RDM Function
"RDM-UID" is the only UID code for CAT-2. RDM allows two way communication between a controller and the unit. CAT-2 support 3 kinds
of sensor information as below.
Status
1
Heater Status
2
Fluid Sensor
3
Pressure Sensor
Value
Description
0-10
No Function
1-100% increase.
11-255
No function when under the forward mode.
0-10
No Function
11-255
1-100% increase
0-85
Down mode
86-171
Up mode
171-255
Forward mode
0-5
Turn off/reset the forced pumping mode
6-253
Hold, no operation
Enable the forced pumping mode and it will be shut down after 10
254-255
seconds. If you need to enable the forced pumping mode again,
please reset the forced pumping mode first.
Value
Description
0
Heating
1
Heating finished
0
Enough fluid
1
Low fluid
0
Enough pressure
1
Low pressure