CALIBRATION AND FEATURES
CALIBRATION INSTRUCTIONS
•
After proper lubrication, place any standard die set in the
compression cone and the pusher plate on top.
•
Set the Micro-Crimp adjuster at "95"
•
Press and hold the start switch bulb.
•
If the ram extends and the crimper shuts off
approximately 1 second after the dies are complete-
ly closed and the pump starts to build pressure, the
crimper is correctly calibrated.
•
If the time to shut off is not approximately
1 second, the crimper must be recalibrated. Reca-
brate as follows:
•
Hold the micrometer barrel with a 5/16 inch open end wrench and
rotate the stem either in or out with a 5/32 inch hex key wrench.
•
If the motor shuts off too quickly or before the dies are complete-
ly closed, rotate the stem in.
•
If the motor does not shut off or shuts off in substantially more
than 1 second, rotate the stem out.
CRIMPER FEATURES
The easily removable Coupling Stop makes
repetitive crimps faster by not having to visu-
ally align the fi tting before each crimp.
li-
The adjustable retraction stop limits the
retraction of the ram to only the amount
required to easily remove the hose and fi t-
ting. This feature saves time when doing
multiple crimps.
Page