SECTION 8
Installing the Blower
1. Refer to the instructions included with the blower for installation.
SECTION 9
Installing the Optional Soffits
1. Refer to the instructions included with the specific soffit(s) you have chosen for
installation.
SECTION 10
Finishing the Installation
1. Install the proper lighting for your specific unit:
Halogen Lamps: Use PAR16 medium base 45W maximum lamps (available separately).
Install by inserting lamp into socket and turning clockwise until lamp is firmly seated.
DO NOT over tighten.
Night Lights: Use 4 watt, candelabra style bulb. Install by removing the snap
fit lens and inserting bulb into socket and turning clockwise until bulb is firmly
seated. DO NOT over tighten.
Heat Lamps: Use type R40, medium base IR 250W max lamps only (available
separately). Install by inserting lamp into socket and turning clockwise until lamp
is firmly seated. DO NOT over tighten.
2. Install the grease filters by inserting the bottom of the filter into the bottom channel
of the hood compressing the spring, then slide the top of the filter into the top
channel of the hood (Figure 18).
Bottom
Channel
Figure 18
SECTION 11
Operation
Controls
Your Range Hood is equipped with two rotary switches with one controlling the lighting
and the other controlling the exhaust fan blower. The light switch has three positions,
HIGH ( ), LOW ( ), and OFF (•). The fan switch has four positions, OFF (•), HIGH (III),
MEDIUM (II), and LOW (I) (Figure 19).
Blower Switch
Figure 19
NOTE: On installation where a One (1) speed blower is utilized, all blower control
speeds operate at the same speed. On installation where a Two (2) speed blower is
utilized, the Medium and High speeds operate at the same speed.
Heat Lamp Controls: For models equipped with heat lamps, two On/Off rocker switch
are located on the front underside of the hood for independent control of the heat
lamps (Figure 19).
A111597016 Rev. B 3-10
Top
Channel
Light Switch
Heat Lamp Switch
www.airkinglimited.com
SECTION 12
Maintenance
CAUTION:
MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL
BEFORE SERVICING THE UNIT.
Grease Filters
Included with your range hood are grease filters along with a grease trough that should
be washed at least once a month. The grease filters are dishwasher safe and should
be washed in a mild soap or detergent. Reverse the instruction in SECTION 10 Finishing
the Installation, to remove the grease filters and trough. If the grease filters become
damaged, replace with Air King Models:
AP1030: Model GF1030 Grease Filters
AP1036: Model GF1036 Grease Filters
AP1830: Model GF1830 Grease Filters
AP1836: Model GF1836 Grease Filters
CAUTION:
ALLOW BULB TO COOL BEFORE REPLACING.
Changing the Lamps
Remove the lamp by turning slightly counter-clockwise and pulling out of the socket.
Replace with a PAR16 medium base 45W maximum Halogen lamp.
Cleaning
CAUTION:
DO NOT USE GASOLINE, BENZINE, THINNER, HARSH CLEANSERS,
ETC., AS THEY MAY DAMAGE THE RANGE HOOD.
1. Clean your range hood with a mild detergent, such as dishwashing liquid, and dry
with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS.
Completely dry before restoring power. NEVER IMMERSE ELECTRICAL PARTS IN
WATER.
2. The blower assembly can be vacuumed when build up (dirt, lint, etc.) accumulates
over time. The blower is permanently lubricated and does not require oiling.
5 of 16