1.4 1520 Wiring

DoorKing
Printer Adapter
P/N 1587-010
(Sold Separately)
Use any SERIAL printer with an RS-232 interface.
Set the printer for 9600 baud, 1 start bit, 8 data bits, 1 stop bit.
Information on setting these parameters should be in your
printer manual.
Maximum wire run for the printer interface is 500 feet using
Belden 9418 wire, or equivalent.
Attach a separate 12 AWG wire to # 3 (earth ground). Attach the
other end of this wire to a good earth ground. This can be a
properly grounded metal conduit, a cold water pipe, or a
grounding rod driven at least 10 feet into the soil. A gooseneck
post anchored or mounted on concrete does not make a good
ground. Avoid any splices in wiring. If a splice is made, it must
be soldered and sealed in a watertight junction box.
Supplied
Transformer
16.5 VAC
20 VA
Power Input
Wire Size
MAX Distance
22 AWG
100 Ft.
20 AWG
200 Ft.
18 AWG
250 Ft.
16 AWG
500 Ft.
Keep power wiring as
short as possible.
Note: 12-24 VDC may also be used to
power the 1520.
Basic Gate Control Components
1520 Card
Reader
6
500 ft MAX
Earth
Ground
Relay
Input
1
2
3
4
5
6
7
8
9
10
11
12
13
14
MASTER
MASTER
CODE
CODE
1505
009
1000
Relay Input Options
Basic Door Control Components
Gate Operator
Gate Operator
is wired to
Normally Open
(NO) relay #6
Lock Power
input.
Switch Input
Postal lock connection. A switch closure
across terminals #7 and #14 activates
Relay for its programmed strike time.
See Section 2.2 Relay Strike Time.
Com
NC
Green
White
Black
Red
500 ft MAX
15
16
17
18
18-Pin
Controller:
Terminal
weigand control device (keypads, card
readers, RF receivers, etc.) can be
connected to the 1520 Controller P/N
1520-081.
Note: Power for a device's external
lighting must be provided from a
separate source when using the 1520
Controller. DO NOT connect external
lighting wires to terminals #1 and #2
of the 1520 Controller.
Card Reader:
Readers are factory wired.
Note: 1520 Card Reader has external
lighting that uses the power
transformer supplied.
1520 Card
Reader
Door
Lock
UL listed
Com
NC
w l
P a
Postal Lock
Wiegand Device
Almost any 26-bit
1520 26-bit Card
Door Locks
Electric strike is wired
to Normally Open (NO)
relay #6 input.
Magnetic lock is wired to
the Normally Closed (NC)
relay #5 input.
Power for electric strike or magnetic
lock is NOT provided by the 1520.
Use separate UL listed power supply.