DIAGRAM OF DRIVER
(
/
(
-
120
277
(
+ (
- (
+ (
- (
NOTES (DMX)
• Wire colors on diagram correspond to colors of driver terminals.
• Default DMX address of each luminaire is 001. Consult a third party
DMX commissioner to modify at time of installation. ALUZ does not
provide DMX commissioning.
• DMX Address must be set for each driver. Default DMX address is 001.
• A DMX Control System (by others) must be used to operate the lighting.
• The last driver in a daisy chain sequence must be terminated.
• Driver load not to exceed 100W.
• For best dimming performance, it is recommended to load drivers to a
minimum of 50% (50W) and a maximum of 80% (80W).
• Up to 28 drivers may be daisy chained together using shielded cable
specifi ed for DMX wiring.
• Ensure DIP Switch 1 is set to ON (Left) to activate 24V operation.
DMX Wiring: Static White
+
(
)
-
(
)
(
)
+
(
)
-
(
)
(
)
DMX Wiring: RGBW
+
(
)
-
(
)
(
)
+
(
)
-
(
)
(
)
DMX Wiring: Dynamic White (DWH)
+
(
)
-
(
)
(
)
+
(
)
-
(
)
(
)
1170 N Red Gum St, Anaheim, CA 92806
aluz.lighting
© ALUZ All Rights Reserved. ALUZ reserves the right to make changes or withdraw specifi cations without prior notice.
A8 Series | LED Tape
ZIZA Tape
(A8-ZIZA-TAPE)
)
+
(
)
-
(
)
(
)
+
(
)
)
-
(
)
)
(
)
+
(
-
(
/ +
(
)
1 / -
(
)
/ +
(
)
/
1
(
)
/
2
(
)
3 /
(
)
/
4
(
)
/ +
(
)
1 /
(
)
2 /
(
)
866.ALUZ.LTG | 714.535.7900
)
- (
)
2
)
- (
)
1
)
+ (
)
- (
)
4
- (
)
3
)
)
)
DMX Daisy Chain
NOTES (DALI)
• Wire colors on diagram correspond to colors of driver terminals.
• DALI commissioning to be performed by a third party at time of
installation. ALUZ does not provide DALI commissioning.
• DALI Address must be set for each driver.
• A DALI Control System (by others) must be used to operate the lighting.
• Driver load not to exceed 100W.
• For best dimming performance, it is recommended to load drivers to a
minimum of 50% (50W) and a maximum of 80% (80W).
• Up to 28 drivers may be daisy chained together using shielded cable
specifi ed for DALI wiring.
• Ensure DIP Switch 1 is set to ON (Left) to activate 24V operation.
DALI Daisy Chain
(DMX & DALI Driver - DRV100-E)

DIGITAL INTERFACE

(
,
)
(
,
)
(
,
)
(
,
)
Installation Instructions
Page 3 of 13
Dimming Protocol
& Wiring Diagrams
-
+
8 / 11 / 2023 / Rev 2