TROUBLE SHOOTING GUIDE
Stong gas odour •
Combustion is
abnormal

SPECIFICATIONS

Model
Description
Gas
Ignition system
Jet Size
Rated pressure (kPa)
Gas consumption at Max
TO BE USED WITH A 2.8 kPa SANS 1237 APPROVED
REGULATOR ONLY, WITH A MINIMUM CAPACITY OF 1kg/hr
Any modification to the hob may cause injury
or property damage.
Any modification to the hob will invalidate the warranty
Gas leak from
hose
Hose is dam-
aged
Burner is not lit
Lack of gas
supply
Flame ports are
clogged
Burner is not
in its correct
position
GDH100
60cm 4 Burner Gas Hob
LPG
Electronic ignition (PZT)
1 x D Battery
0.5mm x 1 - Auxiliary
0.62mm x 2 - Semi rapid
0.9mm x 1 - Wok
2.8kPa
73g/h - Auxiliary burner
127g/h - Semi rapid burner
240g/h - Wok burner
on this appliance.
14
Examine hose
using soap
water,and
replace hose .
Replace it
Re-ignite burner
Replace gas
cylinder
Clean flame
ports
Place burner
components
in the right
position
If you are still unable
to correct the problem
with the information
in this guide , then
you need to contact
your nearest dealer or
manufacturer.