AKO AKOCAM AKO-156331 Руководство - Страница 4
Просмотреть онлайн или скачать pdf Руководство для Контроллер температуры AKO AKOCAM AKO-156331. AKO AKOCAM AKO-156331 4 страницы.
AKO-15613, AKO-156131 (3 Relays)
AKO-15633, AKO-156331, AKO-156332 (6 Relays)
Level 2
FANS control (Evaporator)
Level 3
Description
Fans stop temperature by probe 2
If probe 2 is programmed
Probe 2 differential
Stop fans, when compressor stops?
(No=Connected) (Yes=Disconnected)
Fans status during defrost
(Connected) (Disconnected)
Start-up delay after defrost
Operates if it is higher than Drip Time
Stop fans if the door opens?
(No=Connected) (Yes=Disconnected)
Level 2
ALARM control (Visual)
Level 3
Description
Configuration of temperature alarms
(Relative to SP) (Absolute)
Maximum alarm in probe 1
Minimum alarm in probe 1
Differential Alarms Temperature
Temperature alarm delay from the moment at
which they should operate due to temperature
Temperature alarm delay
in the start-up
Temperature alarm delay from
the end of a defrost
Temperature alarm delay from
digital input disabling
If programmed as "Door contact"
Temperature alarm delay from
digital input enabling
If programmed as "Door contact"
Alarm Relay State
(Connected) (Disconnected)
Level 2
DIGITAL INPUTS
Level 3
Description
Digital Input Nº1 configuration
(Disabled) (Door Contact)
(External alarm) (Severe external alarm)
(Remote defrost) (Remote Energy saving)
(Auxiliary activation) (Low pressure input)
Alarm delay of digital Input Nº 1
Polarity of digital input Nº1
(Normally open) (Normally closed)
Digital Input Nº2 configuration
(Disabled) (Door Contact)
(External alarm) (Severe external alarm)
(Remote defrost) (Remote Energy saving)
(Auxiliary activation) (Low pressure input)
Alarm delay of digital Input Nº 2
Polarity of digital input Nº2
(Normally open) (Normally closed)
Level 2
AUX RELAY
Level 3
Description
AUX relay configuration
(Disabled) (Activated by key)
(Activated by input) (Equal state of equipment)
(Second Defrost) (Pump down control)
Defrost 2 maximum duration
Defrost 2 final temperature
Defrost 2 probe
(Disabled) (Probe 2) (Probe 3)
Pump down duration
Pump down On delay
Level 2
GENERAL STATUS
Level 3
Description
Access password to parameters
and Set Point
Allocation of password to Set Point
Initial parameters:
(YES, configure to "Def" and exit programming)
Registry interval
Address for units with communication
Parameters transfer
(Disabled) (Send) (Receive)
Connected probes (Probe 1) (Probe 1 + 2)
(P
robe
1 + 3) (P
robe
1,2 + 3)
Probe to be displayed
Display mode (1 probe + clock) (1 probe + text)
(Connected probes + clock + text)
Temperature display unit
Decimal point
Probe setting (TEM at S1/REG at S3),
(TEM and REG at S3) (See table "Assignment of entries")
Delay of all functions on power supply switch on
Program version (Information)
Level 2
CONTINUOUS CYCLE
Level 3
Description
Continuous cycle duration
Av. Roquetes, 30-38 | 08812 Sant Pere de Ribes | Barcelona | España
Tel. (34) 938 142 700 | Fax (34) 938 934 054 | e-mail: [email protected] |
Values
Min. Def. Max.
(ºC/ºF)
-40,0
4,0
99,9
(ºC/ºF)
0,1
1,0
20,0
No
No
Yes
No
No
Yes
(min.)
0
3
255
No
No
Yes
Values
Min. Def. Max.
SP
(ºC/ºF)
-40,0 50,0
320
(ºC/ºF)
-40,0 50,0
320
(ºC/ºF)
0,1
1,0
20,0
(min.)
0
30
255
(min.)
0
0
255
(min.)
0
0
255
REMARK: When time parameters are modified, the new values are applied when the current cycle is
(min.)
0
0
255
completed. In order for it to have an immediate effect, switch the controller off and then on again.
(min.)
0
0
255
Con.
Values
Min. Def. Max.
Dis.
(min.)
0
0
255
NO.
Dis.
(min.)
0
0
255
NO.
Values
Min. Def. Max.
Dis.
7- Accessories
(min.)
0
30
255
AKO-14918 portable server, with no power supply, in
(ºC/ºF)
-40.0
8.0
99.9
which parameters programmed in a powered controller
Dis.
can be copied by transfer. Parameters can be transferred
(min.)
1
10
255
again from the server to other identical powered
(sec.)
0
5
60
controllers.
Values
Min. Def. Max.
8- Maintenance
0
0
99
Clean the controller surface with a soft cloth, soap and
No
water. Do not use abrasive detergents, petrol, alcohol or
No
solvents.
(min.)
0
15
60
0
1
255
Dis.
S1
1
1
3
9- Warnings
1SC
The use of the unit without observing the manufacturer's instructions may alter its safety
ºC
ºC
ºF
Yes
qualification. To ensure correct operation of the apparatus, only NTC type probes supplied
TEM
by AKO should be used. Between -40 ºC and +20 ºC, when the probe is extended up to
at S1
1.000 m with minimum 0,5 mm cable, deviation will be less than 0.25 ºC (Probe extension
(min.)
0
0
255
cable ref. AKO-15586)
Values
Min. Def. Max.
(h.)
0
1
24
www.ako.com
AKO-15613, AKO-156131 (3 Relays)
AKO-15633, AKO-156331, AKO-156332 (6 Relays)
Level 2
ENERGY SAVING
Description
Level 3
Set Point during energy saving
Energy saving duration
Level 2
HACCP
Level 3
Description
Delay in registering a event after a temperature alarm
Level 2
LANGUAGE
Level 3
Description
English
Level 2
CLOCK
Level 3
Description
Date (Year Month Day)
Hour (Week_Day Hour Minute)
Defrost 1 (Day Hour Minute)
Defrost 2 (Day Hour Minute)
Defrost 3 (Day Hour Minute)
Defrost 4 (Day Hour Minute)
Defrost 5 (Day Hour Minute)
Defrost 6 (Day Hour Minute)
Defrost 7 (Day Hour Minute)
Defrost 8 (Day Hour Minute)
Energy saving Start (Day Hour Minute)
MESSAGES
PASSWORD
Password request to enter programming parameters or SET POINT
DEFROST
It indicates defrosting is being carried out.
EXTERNAL ALARM
Flashing with temperature
SEVERE EXT.ALARM
Flashing with temperature
Flashing with temperature - probe 1 temperature exceeds the
ALARM HIGH TEMP.
parameter programmed in Maximum alarm in probe 1.
Flashing
ALARM LOW TEMP.
parameter programmed in Minimum alarm in probe 1
ALARM LOW PRESSURE
Flashing
with temperature
probe 1, 2 ou 3 failure (Open circuit, crossed temp.> 110ºC or temp.<-55ºC)
probe 1, 2 or 3 FAILURE
ASSIGNMENT OF ENTRIES ACCORDING TO CONFIG. OF PROBE
TEM at S1/REG at S3 (According to EN12830)
Probe 1
Control, alarms and HACCP probe
Probe 2
Defrost probe (or 2º defrost)
Probe 3
Registry probe (or 2º defrost)
TEM+REG at S3
Probe 1
Control, alarms, HACCP and registry probe
Probe 2
Defrost probe (or 2º defrost)
Probe 3
Product core probe (or 2º defrost)
Equipment including rechargeable electrical batteries:
This unit includes batteries which must be replaced when the device's autonomy
time is below the indicated in the specifications. At the end of the unit's service life
the batteries should be disposed of at a selective refuse collection site or returned
to the manufacturer.
2
AKO ELECTROMECÀNICA, S.A.L.
We reserve the right to supply materials that might vary slightly to those described in our
Technical Sheets. Updated information is available on our website: www.ako.com
Values
Min. Def. Max.
(ºC/ºF)
-40,0
0
(h.)
0
0
Values
Min. Def. Max.
(min.)
0
0
Values
Min. Def. Max.
Values
Min. Def. Max.
with temperature
- The probe 1 temperature is lower than the
- Low pressure switch error with compressor On
Connectors
Input S1
25 and 26
Input S2
23 and 24
Input S3
21 and 22
Connectors
Input S3
21 and 22
Input S2
23 and 24
Input S1
25 and 26
Transfer
Programming
Power supply
320
24
255
AKO-14918
CAMCtrl