Alvarion BreezeNET B Примечание к выпуску - Страница 6

Просмотреть онлайн или скачать pdf Примечание к выпуску для Сетевое оборудование Alvarion BreezeNET B. Alvarion BreezeNET B 6 страниц. Wireless point-to-point bridging solutions
Также для Alvarion BreezeNET B: Брошюра и технические характеристики (4 страниц)

Alvarion BreezeNET B Примечание к выпуску
and to set the Transmit Power parameter to the average Tx Power level before the ATPC was
disabled.
In units operating in the 5.3 GHz band, the following rule must be met for full compliance with
FCC regulations: When operating at 5270 MHz, the Transmit Power parameter in the BU, and
the Maximum Tx Power parameter in the RB served by this BU, should not be set to a value
above "17-Antenna Gain" (The maximum allowed EIRP for 5270 MHz is 17 dBm).
The FTP Client IP address should not be configured with the same value as the unit's IP
address. Attempting to do so will display an error when telnet is used. No error will be raised
when SNMP is used. Note that the FTP settings are not reverted to defaults upon issuing a
"Set Full Operator defaults" command (they do revert to default after executing "Set Full
Factory Defaults").
In units with HW Revision B, Burst Mode cannot be activated when using WEP for data
encryption. In units with HW Revision B, the Burst Mode option will be "blocked" upon trying to
enable it when using WEP for data encryption. This limitation does not apply to units with HW
Revision C.

9. Fixed Issues

In previous versions the prioritization mechanism was disabled when the traffic rate reached
the maximum information rate supported by the RB. This problem was solved.
HTTP://WWW.ALVARION.COM
Page 6 of 6
ALVARION LTD.
21A HABARZEL STREET,
TEL AVIV, 69710,
ISRAEL
TEL: 972-3-6456262
FAX: 972-3-6456222