Operating Instructions and Parts Manual
Operation
(Continued)
2. With the cover uninstalled, add
water to the basin and observe the
float control switch operation.
3. Also, test alarm switch if installed.
4. Secure and seal basin cover.
Do not run your pump in a dry sump.
Do not attempt to
oil the motor. A
special oil has been put in the motor
housing at the factory. Use of any other
oil could damage the pump and WILL
void the warranty.
High Water Level
Low Water Level
Figure 5 - Simplex System
www.blueangelpumps.com
Maintenance
Always disconnect
the electrical
supply before attempting to install,
service, relocate or perform any
maintenance. If the power source is out
of sight, lock and tag in the open (off)
position to prevent unexpected power
application. Failure to do so could result
in fatal electrical shock. Only qualifi ed
electricians should repair this unit.
Improper repair could result in fatal
electrical shock.
1. Let the pump cool for a minimum of
two hours before servicing because
the pump contains hot oil under
pressure and the motor is hot.
On Level
Off Level
Figure 6 - Duplex System
4
2. Disassembly of the motor prior to
expiration of warranty will void the
warranty. If repairs are required, see
troubleshooting chart.
3. Inlet should be kept clean and free
of all foreign objects and inspect
annually. A clogged inlet will
damage pump.
4. Pump should be checked monthly
for proper operation.
This pump contains
dielectric oil for
cooling. This oil can be harmful to
the environment. Check the state
environmental laws before disposing
this oil.
Pump #1
Discharge
Pump #2
Discharge
Alarm
Level