CARE AND MAINTENANCE
• Hook the power cord around the L-shaped tab on
the right side of the machine when facing it.
• The pressure hose is stored on the hose hook
located on the back of the handle.
• DO NOT store the power washer where it
is exposed to freezing temperatures unless
you use an antifreeze designed for pumps.
It is recommended that you use this antifreeze
for storing in freezing temperatures. Freezing
will damage the pump unless this is added to
the power washer. If not using or if storing your
power washer for more than one month, it is
also recommended that an antifreeze is used to
protect the pump.

TROUBLESHOOTING

If you have any questions regarding the product, please call customer service at 1-866-235-5112.
PROBLEM
Unit will not turn on. 1. Make sure the power washer is in the "OFF" position. Plug in the electrical cord
The high pressure
(HP) hose will
not connect/stay
connected to the
spray gun. Is this a
spray gun problem?
14
https://www.kipogeorgiki.gr/
CORRECTIVE ACTION
to a grounded 120 volt outlet (no electrical extension cord should be used). If
the electrical cord will not plug into your outlet, your electrical
outlet is not properly grounded and should not be used. Use another electrical
outlet. Press the reset button on GFCI power box. If the color of red is not visible
in the little window on the GFCI, unplug and plug in again. Press reset, and look
for the red color in the window, this should remain red in color. If the color is
staying red, turn the power switch on the power washer to "ON". Squeeze the
trigger on the spray gun and try again.
2. If this did not correct the problem, try plugging into another electrical outlet and
repeat the above procedure. If it is still not working, call Customer Service at
1-866-235-5112.
1. In most cases, the spray gun is not the problem. The problem is the rubber
sleeve covering the fitting at the end of the high pressure hose. It has likely
slipped up toward the metal tip. To fix: wiggle, twist and/or pull the rubber sleeve
down until the entire tip is visible plus an 1/8 in. of the metal fitting below the
tip. Now try to insert the hose tip into the spray gun. It should "click" into place
and will not come out until the hose is released by pushing in the lever on the
underside of the gun. You may cut away the end of the sleeve with a sharp knife
if unable to move the sleeve down. Be careful not to cut or puncture the hose.