ET Solar ET-P654190 Инструкции по установке и сборке - Страница 6
Просмотреть онлайн или скачать pdf Инструкции по установке и сборке для Солнечная панель ET Solar ET-P654190. ET Solar ET-P654190 12 страниц. Solar modules
Fig 4. Module to grounding rod
3.2 Junction box
The junction box should be fixed on the top end of the module during assembly so as to
prevent the seepage of rain.
ET Solar provides a wiring type box. When the integrated J-box is adopted, no tool is
necessary for wiring. Just connect the modules in series according to "+" or "-". You
can complete complex series and parallel connection easily and quickly using different
electric connectors provided by your supplier.
Connectors provided by different suppliers will not mutually match up. Different
connectors provided by one supplier will not match up either. Only one type of the same
connector from one supplier should be used to ensure the reliability of the electrical
connection.
Module
Male connector Female
ETP672series
1394461-2
ETP654 series
ETP660 series
ETM572 series
PV-KBT3
ETM53680
Series
There are other options in addition to using a wiring type junction box only consisting of
two terminals marked with "+" and "-" to represent the positive and negative terminals of
the power supply. Some junction boxes include three or more terminals. Only those
terminals indicated with "+" and "-" should be connected to the load. The others are
designed for the bypass diodes to reduce the damage to modules caused by hot spots and
Manufacturer
connector
1394462-4
Tyco Electronics
Amp GMBH
PV-KST3
Multi-Contact
USA
Notes
12AWG wire
12AWG wire
6