Fleck 7700 Краткое руководство по эксплуатации - Страница 3

Просмотреть онлайн или скачать pdf Краткое руководство по эксплуатации для Блок управления Fleck 7700. Fleck 7700 12 страниц.

Fleck 7700 Краткое руководство по эксплуатации
8P Vanne 7700 ANG 8/03/05 19:33 Page 3
2 - VALVE INSTALLATION
2.1
Water pressure
A minimum of 1,4 bar of water pressure is required for the regeneration valve to operate effectively.
Do not exceed 8,5 bar ; if you face this case, you should install a pressure regulator upstream the system.
2.2
Electrical connection
An uninterrupted current supply is required. Please make sure that your voltage supply is compatible with your
unit before installation. If the electrical cable is damaged, it must imperatively be replaced by a qualified personal.
2.3
Existing plumbing
Existing plumbing should be in a good shape and free from limescale.
The installation of a pre filter is always advised.
2.4
By-pass
Always provide a by pass valve for the installation, if the unit is not equipped with one.
2.5
Water temperature
Water temperature is not to exceed 43°C, and the unit cannot be subjected to freezing conditions.
2.6
Presentation
Service indicator:
- Valve in service : L.E.D on
- Night regeneration:
flashing L.E.D.
Programmation indicator:
- valve in programmation :
L.E.D on.
3
Regeneration button
Flow indicator:
L.E.D. flashes proportionally
to flow.
Not used
in metrical mode.
Value setting buttons.
7700 VALVE