INSTALLATION
GENERAL INFORMATION
DODGE S-2000 Spherical Roller Bearing mounted units
incorporate a unique way of sealing the internal components
of the bearing while still allowing a full + or - 1 degree of
misalignment. The patented sealing system (Pat. #5,908,249)
has proven effective, due to its constant contact pressure, in
protecting the internal bearing components under maximum
allowable misaligned conditions.
NON-EXPANSION BEARING
1.
Clean shaft and bore of bearing. The shaft should be straight,
free of burrs and nicks, and correct size (see shaft tolerance
table). If used shafting is utilized, then the bearing should be
mounted on unworn section of shafting.
2.
Lubricate shaft and bearing bore with grease or oil to
facilitate assembly. Slip bearing into position. When light
press fit is required, press against the end of the inner ring
of bearing. Do not strike or exert pressure on the housing
or seals.
3.
Bolt bearing to support, using shims where necessary to
align bearing so inner ring does not rub on seal carrier. Use
full shims which extend across the entire housing base.
4.
Determine final shaft position and tighten setscrews in the
locking collar(s) of non-expansion bearing to recommended
torque while the other bearings remain free. Rotate the
shaft slowly under load, if possible, to properly center the
rolling elements with respect to the raceways. Then tighten
setscrews into the locking collar of the remaining bearings to
the recommended torque.
WARNING: Because of the possible danger to persons(s) or
property from accidents which may result from the improper
use of products, it is important that correct procedures be
followed: Products must be used in accordance with the
engineering information specified in the catalog. Proper
installation, maintenance and operation procedures must
be observed. The instructions in the instruction manuals
must be followed. Inspections should be made as necessary
to assure safe operation under prevailing conditions. Proper
guards and other suitable safety devices or procedures as
may be desirable or as may be specified in safety codes
should be provided, and are neither provided by Dodge nor
are the responsibility of Dodge. This unit and its associated
equipment must be installed, adjusted and maintained by
qualified personnel who are familiar with the construction
and operation of all equipment in the system and the
potential hazards involved. When risk to persons or property
may be involved, a holding device must be an integral part of
the driven equipment beyond the speed reducer output shaft.
INSTRUCTION MANUAL FOR
S-2000 SPHERICAL ROLLER BEARINGS
®
5.
Check rotation. If there is any strain, irregular rotational
torque or vibration, it could be due to incorrect alignment,
bent shaft or bent supports. Installation should be rechecked
and correction made where necessary.
EXPANSION BEARING
1.
Clean shaft and bore of bearing. The shaft should be straight,
free of burrs and nicks, and correct size (see shaft tolerance
table). If used shafting is utilized, then the bearing should be
mounted on unworn section of shafting.
2.
Lubricate shaft and bearing bore with grease or oil to
facilitate assembly. Slip bearing into position. When light
press fit is required, press against the end of the inner ring
of bearing. Do not strike or exert pressure on the housing
or seals.
3.
Bolt bearing to support, using shims where necessary to
align bearing so inner ring does not rub on seal carrier. Use
full shims which extend across the entire housing base.
4.
Position expansion bearing in the housing. For normal
expansion conditions, the bearing insert should be positioned
in the center of the housing. To center bearing insert in
housing, move bearing insert to extreme position and mark
shaft. Then using bearing maximum total expansion table,
move bearing insert in opposite direction one-half the total
expansion to center bearing in the housing. If maximum
expansion is required, move bearing insert to the extreme
position in the housing to permit full movement in direction
of expansion. After expansion bearing has been positioned
in the housing, tighten the setscrews in the locking collar to
the recommended torque.
5.
Check rotation. If there is any strain, irregular rotational
torque or vibration, it could be due to incorrect alignment,
bent shaft or bent supports. Installation should be rechecked
and correction made where necessary.
FIELD CONVERSION (RE-OP) OF A NON-EXPANSION
BEARING INTO AN EXPANSION BEARING
All non-expansion bearing sizes can be re-oped to become
expansion bearings. To re-op a non-expansion to an expansion
bearing follow these steps:
1.
Move the snap ring, opposite from the collar side of bearing,
to the outermost snap ring groove.
2.
Install bearing per Expansion Bearing instructions listed
above.
NOTE: Bearing nameplate has a non-expansion Part
Number. When bearing is re-oped the bearing should
be marked as expansion for future reference.
Table 1 - BEARING MAXIMUM TOTAL EXPANSION
Shaft Size (in.)
1-3/8 – 1 1/2
1-11/16 – 3 7/16
3-15/16
4-7/16 – 4 15/16
1
Total Expansion (in.)
3/16
1/14
5/16
3/8