Apply RTV (not supplied) around each of the four housing
bolt holes. This will prevent water from entering the bolt hole
cavities.
Insert the bolts, and torque to the values shown in Table 4.
NOTE: Follow all instructions and precautions shown by
LOCTITE or the equivalent product's manufacturer.
Wipe off any excess sealant and RTV/gasket material.
PLUNGER SCREW
RTL SLEEVOIL
SIZE
WRENCH SIZE
(SOC. HEX)
3-7/16
3/8
3-15/16
3/8
4-7/16
½
4-15/16
5/8
5 -7/16
5/8
6
5/8
7
5/8
8
¾
9
¾
10
¾
12
¾
Plunger screw will be tightened to torque given in Table 4,
following procedure described below.
Cap Loaded Bearings:
To install cap in cap loaded bearings, tighten plunger screw
to torque given in Table 4 while shaft is held down. Mark the
position of the plunger screw. Loosen plunger screw one turn
and loosen shaft hold down.
Next, tighten plunger screw to the mark. Remove shaft hold
down and tighten plunger screw locknut.
Table 4
HOUSING CAP BOLT
TORQUE
THREAD
TORQUE
(IN.-LB.)
SIZE
(IN.-LB.)
850
¾–10
850
¾–10
1260
7/8–9
2500
7/8–9
2500
1–8
2500
1–8
2500
1-1/8–7
3600
1-1/8–7
3600
1¼–7
4800
1¼–7
4800
1½–6
NOTE: Do NOT tighten plunger screw on accompanying
base loaded bearing until cap loaded bearing has been
installed and shaft hold down removed.
BASE LOADED BEARINGS:
Tighten plunger screw to torque given in Table 4 and secure with
locknut.
INSTALLATION OF GROMMETS
Install grommet and grommet plate over coolant pipes.
Apply RTV or a non-hardening sealant on the housing
grommet area and between the grommet and grommet
plates, and around coolant pipes.
1920
1920
2280
2280
PLATES
2640
2640
NUTS
3600
3600
5040
5040
8880
BUSHINGS
GROMMET
Install bushings and nuts on pipes (snug not tight).
Oil level gauge may be located any distance from the pillow block
by use of a coupling and pipe of desired length. The extended
pipe must be supported so that it remains straight and level with
no offsets (use a spirit level—do not guess). Use pipe sealer on
all connections.
When pillow block is arranged for circulating oil, the oil level
is controlled by the drain system and the oil level gage is not
needed
6
AND OIL GAUGE