Step 4: Filter connection to facepiece
1. Align notch on edge of 603
adapter with facepiece
mark in order to properly
align fi lters.
Step 5: Donning respirator & adjusting fi t
1. Place the respirator over
your mouth and nose
and nose and pull head
harness over the crown
of head.
Adjust the straps so the respirator is comfortable and snug, but do not overtighten.
Note: Decrease strap tension by pushing out on back side of buckles.
Note: Use of the EVF does not change donning steps.
Step 6: Positive Pressure User Seal Check
Place the palm of your hand over the center of the EVF and exhale gently. If
facepiece bulges slightly and no air leaks are detected between your face and the
facepiece, a proper seal has been obtained. If faceseal air leakage is detected, repo-
sition respirator on your face and/or readjust tension of the elastic straps to eliminate
leakage. If you cannot achieve a proper seal, DO NOT enter contaminated area.
If you have questions, consult your supervisor or call 3M Technical Service at 1-800-243-4630
(USA) or 1-800-267-4414 (Canada).
Notice: These respirators are not FDA cleared for use as a medical device.
Medical Solutions Division
3M Health Care
2510 Conway Ave.
St. Paul, MN 55144 USA
2. Rotate fi lter assembly
¼ turn clockwise until it is
fi rmly seated. Repeat steps
1-2 for second fi lter.
2. Connect the bottom
straps at the back of the
neck.
Phone: 1-800-228-3957
Web: 3M.com/Medical
Facepiece with properly attached
fi lters shown.
Note: Rotate fi lters counterclock-
wise to remove.
3. Adjust top straps by pull-
ing on ends of straps.
©3M 2021. All rights reserved. 3M and the other marks
shown are marks and/or registered marks.
Unauthorized use prohibited. Used under license in
Canada.
GL_70-2011-7962-2
4. Adjust bottom straps by
pulling on ends of straps.