5. Push / connect the microphone to the Mini XLR connector.
6. Connect a straight wired cable (CAT 5, 5e or 6) fitted with an RJ45 to RJ45
Male connector observing 568B wiring standard.
7. Plug the RJ45 into the socket on the ceiling enclosure. 9-48V Phantom
power is required.
8. Connect the other end of the cable to your preferred audio device (mixer /
DSP). A link cable is supplied for connection to DSP.
Link cable colour code
RJ 45
Cable colour
Pin No.
1
ORANGE/WHITE
2
ORANGE
3
GREEN/WHITE
4
BLUE
5
BLUE/WHITE
6
GREEN
7
BROWN/WHITE
8
BROWN
Warning: Do not pull on the cable once
Function
MIC 3 PHASE +
MIC 3 PHASE -
MIC 2 PHASE +
MIC 1 PHASE +
MIC 1 PHASE -
MIC 2 PHASE -
NOT USED
GROUND
5
installation has been completed
as there is a potential for
damage to a ceiling tile.
Link cable
2
3
1