ASHAPOWER NEON-30 Руководство пользователя - Страница 11

Просмотреть онлайн или скачать pdf Руководство пользователя для Контроллер ASHAPOWER NEON-30. ASHAPOWER NEON-30 14 страниц. Solar mppt charge controller
Также для ASHAPOWER NEON-30: Руководство пользователя (14 страниц)

ASHAPOWER NEON-30 Руководство пользователя
● Note: Before changing the default settings values of the device, ensure the
maximum ampere and voltage ratings applicable for your battery type and brand
(SMF, LEAD-ACID, GEL) This device is not suitable for Lithium Phosphate battery
charging. Blind settings may cause severe damage to the batteries and charge
controller. Default values given are for lead acid batteries. Refer your battery user
manual for voltage and amp settings
● IT IS BETTER TO NOTE DOWN THE DEFAULT SETTINGS VALUES BEFORE MAKING
CHANGES
● NEVER TRY TO CHANGE THE DEFAULT SETTINGS OF THE DEVICE WITHOUT
TECHNICAL ADVICE
ENTERING SETUP MODE:- Before entering setup read user manual carefully.
Connect the charge controller to the desired battery bank. Switch o the device
using MPPT ON/OFF switch (switch 6)
Press and hold ENTER button ( button 3 on the front panel) switch on the device.
Release when the display shows SETUP. Device enters to the setup menu 1. All LED
indicators and fan starts to function. Press the ENTER button again to go to next
menu. ( It is better to note down the default settings values before changing - Refer
Mppt Settings Page - Page 11) .Use the PLUS and MINUS buttons (button 5 and 4)
to increase or decrease the default values. Device saves the changes when kept idle
for 5 seconds or gone through all menus

ENTERING SETUP MODE

CAUTION
11