6.2 Rear Panel

① ②
① . EDID Control Switcher: Default factory setting is TV, leave as if the display
is properly. Switch to STD to use built-in EDID.
[Note]:
1. When EDID switch to TV, the unit will detect the first HDMI output
source ' s EDID and record in the unit. If the first detected output
source is DVI it will pass to next source until the first HDMI source been
detected. The detection priority is HDMI v1.3 > HDMI v1.2 > DVI.
2. When EDID switch to STD the unit will use built-in EDID which supports:
Video → 1080p 12-bit (max) but not supports xvYCC
Audio → PCM 2CH
3. The EDID selection will only activated when the unit is re-plug and
power on.
② . RS-232: Connect to the COM port of your PC for the distant control over
RD-232 channel. Detail specification in section 8.
③ . Video/DDC CAT 5 outputs: Connect each of these output ports with CAT
5 cables to CAT 5 to HDMI receiver and then to display with HDMI cable.
④ . HDMI inputs: Connect input ports to the HDMI or DVI output of your
source equipment such as DVD player or set-top-box.
⑤ . Power: Plug the 5VDC power supply into the unit and connect the
adaptor to AC wall outlet.
⑥ . IR IN: Place the IR receiver cable in front of the display and then use the
existing remote controls to control both sources and display.
⑦ . IR OUT: Place the IR blaster cable in front of the sources and then use the
existing sources remote controls to control the source equipments.