Installation and Maintenance Instructions for
ZX11 Non-Sparking High Purity Transmitter
top of the instrument (Refer to "5. Outline
drawings"). Unit will not provide prescribed
performance if the air inlet is obstructed/
blocked.
• Do not apply excessive force or excessive
bending to the cable once the connector
is attached to the product and the mating
connector.
• Snoop test of the sensor part should be
avoided as this may cause an insulation
resistance defect.
• Prior to commencing operation, it is
recommended to purge the unit with
sufficient inert gas. This will remove any
atmospheric component, particles, and/or
foreign matter within the pipe

5.4 Storage Precautions

• To avoid failure or damage, do not store
product under the following conditions:
• Do not expose to water
• Susceptible to adverse effects due to air
pressure, temperature, humidity, ventilation,
sunlight, particles, salt or sulfur in the air
m
• Do not expose to inclination, vibration or
CAUTION:
shock (including during transportation)
• Do not expose to chemicals (chemicals'
storage area) or gas
• Do not expose to direct sunlight or high
temperature
• Deformation and discoloration of resin parts
may occur when product is stored in a
sealed bag under high temperature and high
humidity environments.

6. WIRING

6.1 Wiring schematic of mating connector
Wire connection and external connection should be carried
out as follows.
Insert the cable with M12 connector (optional) while aligning
to the connector groove on the instrument. Hand-tighten
until the nut does not move. [Tightening torque: 0.4 to 0.5N
CONNECTOR
TERMINAL ARRAY
TERMINAL ARRAY
1
2
3
4
© Ashcroft Inc. 2020, 250 East Main Street, Stratford, CT 06614-5145, USA, Tel: 203-378-8281, Fax: 203-385-0357, www.ashcroft.com
All sales subject to standard terms and conditions of sale. ZX11_Transducer_im_RevA_(I&M011-10278)_06-05-20
m]
2-WIRE SYSTEM
CABLE COLOR
Power Source +
Brown
White
Power Source -
Blue
Black

6.2 Load Resistance

Refer to the following chart for relationship between load
resistance and power supply voltage.
Power Supply & Load Resistance
1000
900
800
700
600
500
400
300
200
100
0
8
10
12
14
R Lmax
Maximum load resistance
Minimum load resistance
[Current output: 4 to 20mA DC (2-wire system)
ZX11
[Lead: Brown]
[Connector: 1]
[Connector: 3]
[Lead: Blue]
When connecting equipment that can generate surge from the
same power supply, it is recommended that a voltage-depen-
dent resistor (varistor) be connected to the pressure transmitter
for protection. In addition, take the following precautions when
wiring:
Do not pull or bend the cable with excessive
force.
When mounting, check the specification rat-
ing of the product and determine the power
supply rating to be used. Once the product
load resistance has been verified, use the
Operating Range
16
18
20
22
24
26
Power Supply (Vdc)
R Lmin
E (V)-10(V) ( )
R L
max
0.02(A)
R Lmin E (V)-26.4(V) , R Lmin ≥o( )
0.02(A)
Non-Hazardous Area
Power
Source [+]
A
15 to
24V dc
4-20mA dc
C
Power
Source [–]
+
-
Receiver
28
30
Connector
4