The following figure shows the final connections.

3.4 Setting up the Dolby Multichannel Amplifier

You need to set up the Dolby Multichannel Amplifier and configure it to receive a Yamaha
Tio1608-D AES67 input stream.
Procedure
1. Connect the amplifier power cord, and press the power button to turn the device on.
2. Connect a CAT5e or greater cable from the COMMAND port to the network.
3. Configure your computer IP address to communicate with the Dolby Multichannel Amplifier
default IP address (192.168.1.143 [or the address you previously configured]) on the
COMMAND port. If using the default IP address, we recommend that you enter an IP address
above 192.168.1.150 and below 192.168.1.254, with a subnet of 255.255.255.0.
4. Open your web browser, and enter the Dolby Multichannel Amplifier COMMAND port default
IP address 192.168.1.143 to display the web client user control screen. (Currently, we
recommend the Google Chrome browser.)
5. Click Network in the navigation bar to display the network parameters (shown in the
following figure), and under the Command section, click Manual for IP configuration. When
prompted for credentials, the default password is
Dolby CP750 7.1 audio for the Dolby Multichannel Amplifier Installation Manual
7 May 2018 Issue 1
password .
Setting up the system
13