Akron 3579 Инструкции по установке - Страница 2

Просмотреть онлайн или скачать pdf Инструкции по установке для Измерительные приборы Akron 3579. Akron 3579 5 страниц. Stop bracket service kit

Bracket Mounting:

1. Rotate the manual override wrench (#56) such that it is oriented on the elevation gear cap (#7)
as shown in Figure 2
2. Place bracket assembly on top of elevation gear cover (#7) as shown in Figure 2.
3. Align the hole at the end of the stop bracket (#203) with the upper exposed hole in the
inlet elbow (#2) as shown in Figure 2.
Figure 2: Bracket Placement
4. Rotate the elevation joint towards vertical until there is enough clearance to insert item 206 into the stop bracket.
This should be around 15°-20° off vertical. Refer to Figure 3.
5. Apply Permabond LM113 or Loctite 222 to the ½"-20 X ½" hex head screw (#206), and insert it into the inlet
elbow hole through the stop bracket using a ¾" socket or wrench. Refer to Figure 3.
6. Apply Permabond LM113 or Loctite 222 to both ¼"-20x1.5" cap screws (#160) and insert each through the slots
on the stop bracket and into the holes in the elevation gear cover (#7) using a 3/16" Allen wrench as shown in Figure 3.
203
2
Page 2
7
56