The following text replaces the redacted text in Step 11 on page 9 of the Hard Drive Replacement document:
If you disconnected power, reconnect it now.
DP600 Firmware Versions 1.5 and earlier:
Replaced hard drives should be initialized one of three ways:
1. Through a software reinstall, or
2. Manually initializing the drive through the 3Ware BIOS as described in section 3.1.2 of the DP600
User's Manual, Issue 1 downloadable from the DP600 web client by clicking on the book icon
displayed when first navigating to the DP600 Web Client from your browser, or
3. Through a remote session with a Dolby engineer who can manually initialize the new drives.
If both RAID drives (physical drives 1 and 2) are replaced at the same time, a clean software reinstall
must be performed, in which case the unit will need to be rebuilt from scratch including installation
of the license file, all hotfolder workorders and upload of all custom profiles.
DP600 Firmware Versions 1.6 and 1.7:
Replaced hard drives should initialize automatically on their own or after a system reboot.
If both RAID drives (physical drives 1 and 2) are replaced at the same time, a software reinstall must
be performed. Use the external system backup option combined with a clean system installation
option during the installation process to recover your unit's settings and profiles.
DP600 Firmware Versions 1.8.19 and later:
Replaced hard drives should initialize automatically on their own or after a system reboot.
If both RAID drives (physical drives 1 and 2) are replaced at the same time, a software reinstall must
be performed. Use the external system backup created at the start of this process to reload the
system settings when prompted during the installation process to recover your unit's settings and
profiles.