3M S-200 Уход и обслуживание
Просмотреть онлайн или скачать pdf Уход и обслуживание для Респираторный продукт 3M S-200. 3M S-200 2 страницы. Supplied air respiratory system
3M
Powered & Supplied Air Respirators
™
3M
When the S-200 system is combined with an approved 3M
respiratory protection.
To maintain protection levels, optimise the effective lifetime of the system and avoid the additional
cost of replacement, it is extremely important to carry out regular checks and maintenance on
Powered and Supplied Air Respirators.
Before Use
•
Inspect Regulator assembly for cracks or loose
connectors
•
Inspect Breathing Tube – ensure it is free from splits
or holes
Replace if necessary
•
Inspect Belt – ensure it is free from splits or tears and
the buckle is undamaged
•
Examine tubes and connectors for cracks and the
seals/sealings rings for damage
•
Examine the 3M Compressed Air Supply Tube for
damage
•
The facepiece should be inspected as per the user
instructions
Replace all damaged paRts immediately to
ensuRe coRRect levels of pRotection
S-200 Supplied Air
™
Respiratory System
Care and Maintenance
Facepiece it forms a supplied air apparatus for
™
Monthly
•
Carry out all the 'Before Use' inspections and create
record of this monthly check for the regulator
After Use
•
Clean casing with cloth dampened with a mild
solution of water and liquid household soap
•
Disinfect with 3M
105 Wipes
™
•
Store in a dry, clean area / locker away from direct
sunlight, high temperatures and solvents
3