Cypress OSM-1000-BRD Краткое руководство по эксплуатации - Страница 2
Просмотреть онлайн или скачать pdf Краткое руководство по эксплуатации для Медиаконвертер Cypress OSM-1000-BRD. Cypress OSM-1000-BRD 2 страницы. Osdp-wiegand converter
Также для Cypress OSM-1000-BRD: Краткое руководство по эксплуатации (2 страниц), Краткое руководство по эксплуатации (2 страниц)
12VDC
Power
Supply
Wiegand
Access
Ground
Control Panel
Ground
Data 0
Data 1
LED Out
Beeper Out
Ground
Digital Input
12VDC
Power
Supply
Power
Ground
Wiegand
Card
Reader
Power
Ground
Data 0
Data 1
LED IN
Status LED Behavior:
white. The startup sequence lasts approximately 5 seconds and the LED will display red, blue, green, white or display
red, green, blue, white.
ACU Mode
OSM-1000 is communicating with PD: the status LED will be blue with green flashes or green with blue flashes. The
status LED will briefly turn red when it receives reader data from the PD.
OSM-1000 is not communicating with PD: the status LED will be blue with slow, green flashes or green with slow,
blue flashes.
PD Mode
OSM-1000 is communicating with ACU: the status LED will be red with blue flashes or red with green flashes.
OSM-1000 has not been polled by the ACU: the status LED will slowly fade from green to off, and back to green.
ACU stops communicating with OSM-1000: the status LED will slowly fade from red to off, and back to red.
Bench Testing:
Bench testing is recommended to avoid troubleshooting issues in the field.
ACU Mode
1. At the bench, connect the OSM unit to the PD and the Wiegand access controller by following the ACU Mode
Wiring Diagram.
2. Observe the OSM unit and PD communicating. Refer to the "Status LED Behavior" section to verify that the OSM
unit is communicating with the PD.
3. If the devices do not communicate, make sure the the baud rate and polling ID match. In the OSDP spec, the
default baud rate is 9600 and the default polling ID is 0.
PD Mode
1. At the bench, connect the OSM unit to the Wiegand reader and ACU by following the PD Mode Wiring Diagram.
2. Observe the OSM unit and ACU communicating. Refer to the "Status LED Behavior" section to verify that the OSM
unit is communicating with the ACU.
3. If the devices do not communicate, make sure the the baud rate and polling ID match. In the OSDP spec, the
default baud rate is 9600 and the default polling ID is 0.
ACU Mode Wiring Diagram
Power
8 - 16 VDC Input
Ground
Data 0
Data 1
LED I/O
Ground
Input 1
Input 0
PD Mode Wiring Diagram
8 - 16 VDC Input
Ground
Data 0
Data 1
LED I/O
Ground
Input 1
Input 0
The OSM-1000-BRD unit has a tri-color LED that can display red, green, blue, and
RS485 -
RS485 +
Ground
Relay N.O.
Relay COM
Relay N.C.
Ground
8 - 16 VDC Input
RS485 -
RS485 +
Ground
Relay N.O.
Relay COM
Relay N.C.
Ground
8 - 16 VDC Input
12VDC
Power
Supply
Power
Ground
OSDP
Reader
Power
Ground
RS485 -
RS485 +
OSDP Access
Control Panel
RS485 -
RS485 +
Card