Operating Manual - neWR-5 Remote Control for NE Products
6)  Zone Source Selection - This function is used to assign a button to select one or more 
inputs for the defined zone (Select Zone Outputs) under neWR-5 control.  Any function button can 
have any combination of inputs as sources.  A zone source selection button is green when selected, 
and red when unselected.  When multiple zone source select buttons are assigned different or over-
lapping inputs, each button will simply add to or subtract from the other's input selections.  How-
ever, if the Exclusive Source Selection box is checked in the zone setup, only the currently selected 
button's inputs will be used for that zone.
The <Disable Zone Level Control> checkbox allows input source selections to be changed from 
the neWR-5, but not the overall output gain for that zone.  The output gain can still be adjusted from 
the target device software, but the neWR-5 user is locked out from making output zone gain changes.
7)  Logic Output Active High - This allows the user to toggle the Logic Output assigned pin to 
the button.  The switch turns green when the output is high.
8)  Logic Output Active Low- The switch turns green when the output is Low.
9)  Matrix Mixer - This is used to select one or more inputs for the zone under neWR-5 con-
trol, but  allows level control of that group at the dsp matrix mixer point instead of the output.  Select 
one or more Zone Output(s) in the Zone Setup to use the Matrix Mixer function
Security
In addition to the hardware lockout available on the neWR-5, there are multiple user/multiple 
levels of software protection assignable to the neWR-5 within the Security tab, from full access to 
view only.  The security data is stored within the neWR-5 itself, not Protea NE Software. Passwords
are case sensitive. Be sure to write down the password and store in a convenient place for future 
reference.  
Network Properties
Hardware, device, and device network configuration details are displayed in the network prop-
erties tab.   This includes the current neWR-5 firmware revision.
Flash Reprogram
The firmware, meaning the internal program which runs on the neWR-5, can be updated easily 
over the network.  Look in network properties for the current firmware revision.  To obtain the latest 
firmware, visit the Ashly Web site, locate and save it to the computer, then run <Flash Reprogram> 
under the Device Options menu.  The LED displays "Pr" during the reprogramming process.
Factory Reset
To restore factory default settings, a factory reset can be performed by connecting power to the 
unit while holding the top function button down for 10 seconds, during which time a countdown will 
occur on the LED display.  Releasing the button at any time prior to completion of the countdown 
stops the process.  Upon completion of the countdown, the LED displays "Fr" until the neWR-5 is 
reset.