Ashly ne4400 Руководство по эксплуатации - Страница 11

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Компьютерное оборудование Ashly ne4400. Ashly ne4400 20 страниц. Network enabled dsp processor
Также для Ashly ne4400: Технические характеристики (3 страниц), Руководство по эксплуатации (20 страниц), Руководство (20 страниц)

Ashly ne4400 Руководство по эксплуатации
Operating Manual - ne8800, ne4800, ne4400
Metering
Three separate metering tabs are available for viewing across all channels the autoleveler, compressor/gate actions, or
overall input and output signal levels. Note: In addition to the fixed meter tabs, individual meter control objects can be placed
in the main software canvas and assigned to an input or output for a customized meter display.
Logic I/O
This tab is where the 12V digital logic I/O pins on the NE processor's back panel are assigned their functions. Pins des-
ignated as logic inputs, upon contact closure with the logic ground, can recall a preset, utilize 'push to talk' to unmute a mic
input and trigger a ducker, or be assigned to have no function. Do not wire contact closure switches to an external ground. If
a logic input pin is unconnected, it will be internally pulled high. If actually driven by an external logic source, any voltage
greater than +2.3VDC will be high.
Pins designated as logic outputs will issue either a logic high level (+12VDC at 10mA) or logic low level (0VDC sink at
100mA) when the GPO (general purpose output) function is selected. The high or low output state is a function of the currrently
loaded preset, or can be the result of a WR-5 button programmed to set the logic output to active high or active low. The logic
outputs are current limited to sourcing no more than 10mA so that these outputs can be directly wired to LED indicators.
Security
The security tab allows several levels of user ID/password protected access. The default user ID is Admin, with no pass-
word until the principle operator, presumably the Admin, enters one. Up to six additional users can be added, each with their
own password and access rights assigned by the Admin.
Network Properties
This is where to find the exact hardware and firmware configuration of a specific device, as well as device network at-
tributes. Also found here is an <Identify Device> button which flashes the Com LED on the face panel when clicked.

10. REMOTE CONTROL

10.1 WR-5 Programmable Zone Controller (Remote Data)
The WR-5 is a microprocessor based programmable remote control unit which can be used with the NE processor. The
WR-5 is designed to fit into a standard electrical wall box. Up to four WR-5 remotes can be phantom powered from one proces-
sor. Additional remotes can be powered by using the Ashly RPS-18 remote power supply. Each of six buttons on the WR-5 can
be programmed to engage one of the following functions. listed below. The up/down buttons are used to control the designated
parameter, if applicable
1) Preset Recall
2) Preset Scroll Mode
3) Gain Control
4) Channel Engage/Mute
5) Zone Source Selection
6) Logic Output Active High
7) Logic Output Active Low
8) Matrix Mixer
(check the Ashly website for updated or additional remote control models)
Ashly WR-5 Programmable Controller
11