Front Housing LED Indications
Off (Green)
Steady
Security Off, all conditions Normal (no trouble)
Blinking
Trouble e.g. Phone line cut, RS485 comms
failure. Trouble Condition is displayed
Arm (Red)
Steady
System armed, No alarm
Blinking
Alarm / Alert condition .
AC (Red)
Steady
Mains Power failure.
Blinking
Comfort Battery voltage low due to prolonged
power failure.Battery may need to be replaced.
Msg (Green)
Steady
Blinking
New message from phone. Press # to hear who
the message is for. Sign in with user code to hear
the message
Mic (Red)
Steady
Installation
KP04A should be installed in an indoor location, not
outside the premises for security reasons.
Remove the screw at the base and pull the front
housing from the back housing.
Mount the back housing on the wall using the
screws supplied.
Connect the 6 wires from the terminal blocks (JP1,
JP2 , JP3) to the Comfort PCB according to the
signal name. Note the 12V should be connected to
the 12V terminal on Comfort, not S12V
If more than one Keypad/Door Station is used,
connect their 12V and ground wires back to
Comfort individually, not in series to avoid
excessive voltage drop along the cable.
Comfort II Text Synchronisation
New Internal message. Press # to hear who the
message is for. Sign in with user code to hear
the message
Microphone ON for Recording or Intercom