Wall Mount Access
LCD Screen
Menu Button
LED Indicator
Up Button
Down Button
Enter Button
Equipment Power
Connection
Features of your Blueprint Compact Digital
CO
Controller, BCDCC-1
2
• Precisely controls CO
generating devices
2
• Remote sensor on a 16' cable accurately monitors CO
• Integrated photocell allows day, night or 24-hour CO
• Stores minimum and maximum CO
• Wall mountable
• 3-year warranty
Installation
1. Connect the unit to a 120V power source.
2. If desired, mount the unit to the wall or alternate support using
the mounting tab.
3. Program desired settings.
4. Position remote sensor in best location to accurately gauge CO
levels for proper unit functioning.
5. Connect the device to be controlled.
Caution
Ensure the device being connected to the
Controller has the proper voltage and will not
exceed the maximum amperage rating
of he unit.
Warning
Do not expose the unit to water.
Factory Settings
• CO
Set-point: 1250 ppm
2
• Photocell mode: Day
• CO
Sensor: 380 ppm
2
• CO
Deadband: 50 ppm
2
• CO
Mode: Increase
2
LED Indicator
levels
2
control
2
values
2
2
Thank you for choosing to grow with Blueprint
Controllers! Your satisfaction and success are
important to us. For best results, carefully read
the following instructions before using your
Blueprint Compact Digital CO
Specifications
Input Voltage: 120V
Maximum Amperage: 14.5A @ 120V
CO
Sensor Type: NDIR (Nondispersive Infrared)
2
CO
Control Range: 350-2500 ppm
2
CO
Deadband: 50-250 ppm
2
Dimensions: 3" x 6" x 3.5"
Restoring Factory Settings
Factory settings can be reinstated at any time by pressing and
holding the MENU and UP arrow buttons for 3 seconds, then
pressing ENTER.
LCD Screen
Current Mode
Photocell Mode
Selecting CO
Settings
2
CO
Set-point: To set the CO
2
the controller, press the MENU button to display the first menu
item. Use the UP and DOWN arrow buttons to scroll through and
find "Set CO
Setpoint" on the LCD screen. To change the setting,
2
press the ENTER button. The current setting will be highlighted to
indicate the setting can be changed. Use the UP and DOWN arrow
buttons to change the setting. Press the ENTER button a second
time to accept the new setting and store it in memory.
Controller.
2
Hanger
CO
Sensor
2
Photocell
CO
Level
2
level that will be maintained by
2
rev:112013