Installation
• Mount the Controller on the wall. Place the remote sensor
at plant height in an area with good air circulation. Avoid
placing the sensor in a location with direct, intense exposure
to light.
• Connect the sensor cable to the bottom of the unit using the
quick- disconnect screw.
• Plug the Controller into a 120V NEMA 5-15 wall outlet.
• Flip the switch on the bottom of the unit to the ON position.
• Program desired settings before connecting any devices.
• Plug in and power on devices to be regulated by the Controller.
Caution
Ensure the devices being connected to the
Controller have the proper voltage and will
not exceed the maximum amperage rating
of the unit.
Warning
Do not expose the unit to water.
Factory Settings
The Controller is preprogrammed with the following
factory settings:
• Temperature Day Setting: 80°F
• Temperature Night Setting: 70°F
• Temperature Deadband: 3°F
• Day/Night Setting: 50% RH
• Humidity Mode: Decrease
• Humidity Deadband: 5% RH
• CO
Mode: Dayfree
2
• CO
On Time Duration: 1 minute
2
• CO
Off Time Duration: 30 minutes
2
• Temperature and Humidity Lock: Split
Restoring Factory Settings
Hold the "Enter/Reset" and DOWN arrow buttons for 3 seconds.
The display will read "f.Set." Press the "Enter/Reset" button again
to restore the default factory settings. When the process is
complete, the display will read "donE." Note: It may take up to 15
seconds to complete the process.
Error LEDs
When the Controller is functioning normally, the ambient
temperature and humidity will change slowly but steadily. If the
Controller does not detect a change in temperature or humidity
within a 1-hour period, the unit will deactivate the affected output
and the corresponding green error LED will flash to indicate
which device may be malfunctioning. Ensure the device and
remote sensor are functioning properly. To reset the error, press
the "Enter/Reset" button.
Adjusting Photocell Sensitivity
• Hold the DOWN arrow button for 3 seconds. The current
setting will be displayed.
• Press the UP arrow button to increase the number
displayed, decreasing the amount of light required to
activate the photocell.
• Press the DOWN arrow button to decrease the number
displayed, increasing the amount of light required to
activate the photocell.
• Press "Enter/Reset" to accept the new setting.
Selecting Temperature Settings
Temperature Display: Hold the UP and DOWN arrow
buttons for 3 seconds to change the temperature display
from Fahrenheit to Celsius.
Temperature Day: To set the temperature at which the
cooling output will be activated during the day, press the "Day
Setting" button. The display will read "dAy__F." Use the UP
and DOWN arrow buttons to adjust the setting. Press "Enter/
Reset" to accept the new setting.
Temperature Night: To set the temperature at which the
cooling output will be activated during the night, press the
"Night Setting" button. The display will read "nit__F." Use the
UP and DOWN arrow buttons to adjust the setting. Press
"Enter/Reset" to accept the new setting.
Temperature Deadband: To set the temperature deadband,
press the "Deadband" button under "Temp." The display will
read "d.b___F." Use the UP and DOWN arrow buttons to
adjust the setting. Press "Enter/Reset" to accept the
new setting.
Min/Max Temperature: Press the "Min/Max Temp" button to
display the minimum and maximum recorded temperature
values. Press the button again to cycle through the values.
Press "Enter/Reset" to reset a displayed value.
Selecting Humidity Settings
Humidity Day: To select the humidity level at which the
humidity output will be activated during the day, press the
"Day/Night Setting" button. The display will read "dAy_rH."
Use the UP and DOWN arrow buttons to adjust the
setting. Press "Enter/Reset" to accept the new setting.
Humidity Night: To select the humidity level at which the
humidity output will be activated at night, press the "Day/
Night Setting" button twice. The display will read "nit_rH." Use
the UP and DOWN arrow buttons to adjust the setting. Press