MODEL: OUTLANDER 19

Alcove Installation

Your appliance may be installed using a listed double wall
connector, such as Security DL6 in Canada, the Simpson
Duravent Plus DVL in the USA or an equivalent double wall
connector, into an alcove having a depth of no more than 4
feet and a height of at least 6'3". The minimum clearance are
as shown.
PARALLEL & CORNER
Ceiling (G)
Side wall (H)
Sidewall to flue (I)
Blackwall (J)
Blackwall to flue (K)

Floor protection

If the appliance is to be installed on top of a combustible floor, it must be placed on an approved non-combustible hearth pad,
that extends 8" (203 mm) beyond the appliance sides and back and 18" (457 mm) in Canada / 16" (406 mm) in the USA to the front.
The reduced clearance from the back of the appliance may result in the appliance pad terminating shorter than 8" (203 mm)
beyond the appliance.
note:
Floor protection is required for spark and ash shielding, but not for limiting floor temperatures from the radiant heat
of the appliance. The appliance was designed and safety-tested so that without any protection, the floor would not
overheat.
Refer to local building codes for suitable floor protection materials.
K
J
J
I
SINGLE WALL CONNECTOR
CANADA
USA
note:
If a section of horizontal chimney connector is used, floor protection is required under the
chimney connector and 2" (51 mm) beyond each side.
Ambiance® Fireplaces & Grills
F
ALCOVE
N/A
MINIMUM FLOOR PROTECTION
FRONT (L)
18" (45.7 cm)
16" (406 mm)
www.ambiancefireplaces.com
OUTLANDER
WOOD COLLECTION
A
B
19"
(48.3cm)
28
/
"
7
ALCOVE
8
(733.4mm)
DOUBLE WALL CONNECTOR
7" (190.5 cm)
19" (48.3 cm)
28.875" (73.3 cm)
12.5" (31.8 cm)
16" (40.6 cm)
SIDES (M)
BACK (N)
8" (203 mm)
8" (203 mm)
48" (122cm)
MAX